How to Select an Interface Relay for PLC Outputs
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
The Siemens 6ED1055-1CB00-0BA2 is a LOGO! DM8 24 expansion module for LOGO! 8, adding 4 digital inputs and 4 transistor digital outputs at 24 V DC. Outputs are rated 0.3 A each with short-circuit protection, and the module mounts on a 35 mm DIN rail alongside the base LOGO! unit. Switching frequency reaches 10 Hz with a resistive load.
The transistor outputs at 0.3 A per channel with a 10 Hz switching frequency on resistive loads suit driving PLC or relay coil inputs and pilot indicators directly, rather than switching motor loads that a relay-output DM8 variant would handle at higher current. Matching the 24 V DC supply and I/O voltage to the LOGO! 8 base module avoids adding a separate power supply just to expand I/O count. Choose this module over a smaller expansion when a project needs the extra 4 DI/4 DO in one add-on rather than stacking multiple smaller modules.
Expanding digital I/O count on LOGO! 8-based control panels for small machine sequencing, building automation, and simple relay-logic replacement where additional inputs or transistor outputs are needed beyond the base unit.
| Mounting | on 35 mm DIN rail, 2 spacing units wide |
|---|
| Rated value (DC): 24 V DC | Yes |
|---|---|
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Number of digital inputs | 4 |
|---|---|
| Input voltage: Type of input voltage | DC |
| Input voltage: for signal "0" | < 5 V DC |
| Input voltage: for signal "1" | > 12 V DC |
| Input current: for signal "0", max. (permissible quiescent current) | 0.88 mA |
| Input current: for signal "1", typ. | 2.1 mA |
| Input delay (for rated value of input voltage) for standard inputs: at "0" to "1", max. | 1.5 ms |
| Part number | 6ED1055-1CB00-0BA2 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4034106029432 |
| ETIM class | EC001419 |
| eCl@ss | 27242204 |
| Number of digital outputs | 4 |
|---|---|
| Short-circuit protection | Yes |
| Output current: for signal "1" rated value | 0.3 A |
| Parallel switching of two outputs: for uprating | No |
| Switching frequency: with resistive load, max. | 10 Hz |
| Switching frequency: with inductive load, max. | 0.5 Hz |
| Emission of radio interference acc. to EN 55 011: Limit class B, for use in residential areas | Yes |
|---|
| IP degree of protection | IP20 |
|---|
| CE mark | Yes |
|---|---|
| CSA approval | Yes |
| UL approval | Yes |
| FM approval | Yes |
| developed in accordance with IEC 61131 | Yes |
| according to VDE 0631 | Yes |
| Marine approval | Yes |
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 59.1 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 5.82 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 53.6 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -0.373 kg |
| Ambient temperature during operation: min. | -20 °C; No condensation |
|---|---|
| Ambient temperature during operation: max. | 55 °C |
| Width | 35.5 mm |
|---|---|
| Height | 90 mm |
| Depth | 58 mm |
| Miscellaneous Manufacturer Declara- | tion |
|---|
| Net weight | 0.129 kg |
|---|---|
| Country of origin | CN |
| Shipping weight | 0.629 kg |
| Ships from | Türkiye |
| Dispatch | 13 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of 6ED1055-1CB00-0BA2 is 0.3 A.
The tariff (HS) code on file for 6ED1055-1CB00-0BA2 is 85389091.
The EAN (GTIN) of 6ED1055-1CB00-0BA2 is 4034106029432.
6ED1055-1CB00-0BA2 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.