Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
The Siemens 3TG1010-0AG2 is a relay from the SENTRON/SIRIUS 3TG1 series. Power relay, AC-3, 8.4 A, 4 kW / 400 V, 3-pole, 110 V AC, 45-450 Hz, auxiliary contacts: 1 NO, screw terminal. Supplied by Stoklink for industrial and commercial low-voltage applications.
The Siemens 3TG1010-0AG2 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3TG1 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.
| consumed active power | 4 W |
|---|---|
| reference code according to IEC 81346-2 | K |
| Substance Prohibitance (day/month/year) | 07/01/2006 |
| ambient temperature during operation | -25 ... +55 °C |
| number of poles | 4 |
| number of NO contacts for main contacts | 3 |
| number of NC contacts for main contacts | 0 |
| type of voltage | AC |
| operational current: at AC-1 at 400 V rated value | 20 A |
| operational current: at AC-3 at 400 V rated value | 8.4 A |
| operational current: at AC-3e at 400 V rated value | 6.4 A |
| operating power: at AC-3 at 400 V rated value | 4 kW |
| operating power: at AC-3e at 400 V rated value | 3 kW |
| control supply voltage at AC: at 50 Hz rated value | 110 V |
| control supply voltage at AC: at 60 Hz rated value | 110 V |
| supply voltage frequency for auxiliary and control circuit rated value | 45 ... 450 Hz |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 1 |
| number of CO contacts for auxiliary contacts | 0 |
| fastening method side-by-side mounting | Yes |
| fastening method | screw and snap-on mounting onto 35 mm DIN rail |
| height | 62 mm |
| width | 36 mm |
| depth | 60 mm |
| type of electrical connection: for main current circuit | screw-type terminals |
| type of electrical connection: for auxiliary and control circuit | screw-type terminals |
| device type according to ISO 13849-1 | 3 |
|---|---|
| overdimensioning according to ISO 13849-2 necessary | Yes |
| Part number | 3TG1010-0AG2 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4011209045033 |
| ETIM class | EC000066 |
| eCl@ss | 27371003 |
| safety device type according to IEC 61508-2 | Type A |
|---|
| protection class IP on the front according to IEC 60529 | IP00 |
|---|
| Net weight | 0.148 kg |
|---|---|
| Package dimensions | 187 × 131 × 70 mm |
| Country of origin | Turkiye |
| Shipping weight | 0.648 kg |
| Dispatch | 25 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 31 Oct 2026
The rated current of 3TG1010-0AG2 is 8.4 A.
The rated operational voltage of 3TG1010-0AG2 is 400 V AC.
The control voltage range of 3TG1010-0AG2 is 110 V.
The tariff (HS) code on file for 3TG1010-0AG2 is 85364900.
The EAN (GTIN) of 3TG1010-0AG2 is 4011209045033.
3TG1010-0AG2 ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery. Stock items are dispatched within 1–2 business days.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.