Part number
LC1D95G7
Model no
LC1D
$487.60 On request Dispatch —· Worldwide delivery

Schneider Electric LC1D95G7 TeSys Deca LC1D 3P 3NO AC-3 95 A 120 V AC Coil 1NO+1NC Contactor

TeSys Deca 3P contactor, 95 A AC-3 (45 kW at 400 V), up to 1000 V AC, 120 V AC 50/60 Hz coil, 1NO+1NC.

Rated current
95 A
Rated operational voltage
1000 V AC
Motor power
45 kW
Control voltage
120 V
Poles
3P
EAN
3389110451269
Description

About the LC1D

The Schneider Electric LC1D95G7 is a TeSys Deca 3-pole contactor rated 95 A in AC-3 at up to 440 V, which corresponds to 45 kW at 380/400 V. It has three normally open power poles for circuits up to 1000 V AC, a 120 V AC 50/60 Hz coil and a built-in 1NO+1NC auxiliary block with a mirror-certified NC contact. The 85 mm wide body mounts on DIN rail or plate.

Certifications & Standards

  • CE
  • UKCA
  • UL
  • CSA
  • CCC
  • EAC
  • CB Scheme
  • Marine
  • IEC 60947-4-1
  • IEC 60947-5-1
  • EN 60947-4-1
  • EN 60947-5-1
  • UL 60947-4-1
  • CSA C22.2 No 14

Selection Notes

The 120 V AC 50/60 Hz coil suits North American 120 V control circuits and also runs on 50 Hz supplies, so one coil code covers both frequencies. The key rating is 95 A AC-3 at up to 440 V (45 kW at 400 V); the 125 A figure is the resistive AC-1 rating and should not be used for motor sizing. The power circuit is rated up to 1000 V AC, while the AC-3 motor power stays at 45 kW at 660/690 V and at 1000 V. The coil has no built-in suppressor module, so surge suppression has to be added externally where the control circuit requires it.

Specification

Full specification

74 values · Last verified 24 Nov 2026

Main 10

Range TeSys
Range of Product TeSys Deca Advanced
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load, Motor control
Utilisation category AC-3, AC-3e, AC-1, AC-4
Poles description 3P
[Ue] rated operational voltage Power circuit <= 1000 V AC 25...400 Hz
[Ie] rated operational current 95 A (at <140 °F (60 °C)) at <= 440 V AC-3 for power circuit, 125 A (at <140 °F (60 °C)) at <= 1000 V AC-1 for power circuit, 95 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 120 V AC 50/60 Hz

Complementary 37

Motor power kW 25 kW at 220/230 V AC 50/60 Hz (AC-3), 45 kW at 380/400 V AC 50/60 Hz (AC-3), 45 kW at 415/440 V AC 50/60 Hz (AC-3), 55 kW at 500 V AC 50/60 Hz (AC-3), 45 kW at 660/690 V AC 50/60 Hz (AC-3), 45 kW at 1000 V AC 50/60 Hz (AC-3), 25 kW at 220/230 V AC 50/60 Hz (AC-3e), 45 kW at 380/400 V AC 50/60 Hz (AC-3e), 45 kW at 415/440 V AC 50/60 Hz (AC-3e), 55 kW at 500 V AC 50/60 Hz (AC-3e), 45 kW at 660/690 V AC 50/60 Hz (AC-3e), 45 kW at 1000 V AC 50/60 Hz (AC-3e), 15 kW at 400 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating 7.5 hp at 120 V AC 60 Hz for 1 phase motors, 15 hp at 230/240 V AC 60 Hz for 1 phase motors, 30 hp at 200/208 V AC 60 Hz for 3 phase motors, 30 hp at 230/240 V AC 60 Hz for 3 phase motors, 60 hp at 460/480 V AC 60 Hz for 3 phase motors, 60 hp at 575/600 V AC 60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit, 125 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A 104 °F (40 °C) - 1 s for power circuit, 800 A 104 °F (40 °C) - 10 s for power circuit, 400 A 104 °F (40 °C) - 1 min for power circuit, 135 A 104 °F (40 °C) - 10 min for power circuit, 140 A - 100 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 100 A - 1 s for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1, 200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1, 7.2 W AC-3, 7.2 W AC-3e
[Ui] rated insulation voltage Power circuit 1000 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1, B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 4 Mcycles
Electrical durability 1.2 Mcycles 95 A AC-3, 1.3 Mcycles 125 A AC-1, 1.2 Mcycles 95 A AC-3e
Control circuit type AC 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.8...1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 50 Hz, 0.85...1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 60 Hz, 0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz, 1...1.1 Uc (131…158 °F (55…70 °C)):operational AC 50/60 Hz
Inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)), 245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)), 26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 6…10 W at 50/60 Hz
Operating time 20...35 ms closing, 6...20 ms opening
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end, Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible without cable end, Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: flexible without cable end, Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible with cable end, Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) - cable stiffness: flexible with cable end, Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: solid without cable end, Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: solid without cable end
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2, Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm, Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm), Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Mounting Support Plate, Rail

Environment 14

Standards EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, CSA C22.2 No 14, UL 60947-4-1, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, IEC 60335-1:Clause 30.2
Product Certifications CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
IP degree of protection IP20 front face IEC 60529
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40…140 °F (-40…60 °C), 140…158 °F (60…70 °C) with derating
Operating altitude 0...9842.52 ft (0...3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz), Shocks contactor open 8 Gn for 11 ms), Vibrations contactor closed 3 Gn, 5...300 Hz), Shocks contactor closed 10 Gn for 11 ms)
Height 5 in (127 mm)
Width 3.3 in (85 mm)
Depth 5.1 in (130 mm)
Net Weight 3.55 lb(US) (1.61 kg)
Show all 74 specifications ↓ Show less ↑13 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number LC1D95G7
Type designation LC1D
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110451269

Contractual warranty 1

Warranty (in months) 18

Logistics 4

Country of origin CZ
Shipping weight 1.61 kg
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 24 Nov 2026

Documents

Documents for LC1D95G7 4

Certifications

Certifications and standards

  • UL
  • CSA
  • CE
  • UKCA
  • CCC
  • EAC
  • CB Scheme
  • Marine
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • CSA C22.2 No 14
  • UL 60947-4-1
  • IEC 60335-2-40:Annex JJ
  • UL 60335-2-40:Annex JJ
  • IEC 60335-1:Clause 30.2
Quick answers

Questions about the LC1D

What is the rated current of LC1D?

The rated current of LC1D is 95 A.

Which supply voltage is LC1D rated for?

The rated operational voltage of LC1D is 1000 V AC.

What motor power is LC1D rated for?

The rated motor power of LC1D is 45 kW.

Which control voltage does LC1D need?

The control voltage range of LC1D is 120 V.

What is the HS code of LC1D for customs?

The tariff (HS) code on file for LC1D is 853649.

What is the EAN of LC1D?

The EAN (GTIN) of LC1D is 3389110451269.

How is LC1D delivered, and how fast?

LC1D ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric Schneider TeSys Deca

Brand
Schneider Electric
Series
Schneider TeSys Deca
Series page →
Series

Other series in Contactors

$487.60 On request
Quote

Get a Quote

LC1D

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LC1D95G7

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart