Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
TeSys Deca 3P contactor, 95 A AC-3 (45 kW at 400 V), up to 1000 V AC, 120 V AC 50/60 Hz coil, 1NO+1NC.
The Schneider Electric LC1D95G7 is a TeSys Deca 3-pole contactor rated 95 A in AC-3 at up to 440 V, which corresponds to 45 kW at 380/400 V. It has three normally open power poles for circuits up to 1000 V AC, a 120 V AC 50/60 Hz coil and a built-in 1NO+1NC auxiliary block with a mirror-certified NC contact. The 85 mm wide body mounts on DIN rail or plate.
The 120 V AC 50/60 Hz coil suits North American 120 V control circuits and also runs on 50 Hz supplies, so one coil code covers both frequencies. The key rating is 95 A AC-3 at up to 440 V (45 kW at 400 V); the 125 A figure is the resistive AC-1 rating and should not be used for motor sizing. The power circuit is rated up to 1000 V AC, while the AC-3 motor power stays at 45 kW at 660/690 V and at 1000 V. The coil has no built-in suppressor module, so surge suppression has to be added externally where the control circuit requires it.
| Range | TeSys |
|---|---|
| Range of Product | TeSys Deca Advanced |
| Product or Component Type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load, Motor control |
| Utilisation category | AC-3, AC-3e, AC-1, AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit <= 1000 V AC 25...400 Hz |
| [Ie] rated operational current | 95 A (at <140 °F (60 °C)) at <= 440 V AC-3 for power circuit, 125 A (at <140 °F (60 °C)) at <= 1000 V AC-1 for power circuit, 95 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit |
| [Uc] control circuit voltage | 120 V AC 50/60 Hz |
| Motor power kW | 25 kW at 220/230 V AC 50/60 Hz (AC-3), 45 kW at 380/400 V AC 50/60 Hz (AC-3), 45 kW at 415/440 V AC 50/60 Hz (AC-3), 55 kW at 500 V AC 50/60 Hz (AC-3), 45 kW at 660/690 V AC 50/60 Hz (AC-3), 45 kW at 1000 V AC 50/60 Hz (AC-3), 25 kW at 220/230 V AC 50/60 Hz (AC-3e), 45 kW at 380/400 V AC 50/60 Hz (AC-3e), 45 kW at 415/440 V AC 50/60 Hz (AC-3e), 55 kW at 500 V AC 50/60 Hz (AC-3e), 45 kW at 660/690 V AC 50/60 Hz (AC-3e), 45 kW at 1000 V AC 50/60 Hz (AC-3e), 15 kW at 400 V AC 50/60 Hz (AC-4) |
|---|---|
| Maximum Horse Power Rating | 7.5 hp at 120 V AC 60 Hz for 1 phase motors, 15 hp at 230/240 V AC 60 Hz for 1 phase motors, 30 hp at 200/208 V AC 60 Hz for 3 phase motors, 30 hp at 230/240 V AC 60 Hz for 3 phase motors, 60 hp at 460/480 V AC 60 Hz for 3 phase motors, 60 hp at 575/600 V AC 60 Hz for 3 phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 140 °F (60 °C)) for signalling circuit, 125 A (at 140 °F (60 °C)) for power circuit |
| Irms rated making capacity | 1100 A at 440 V AC for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 1100 A 104 °F (40 °C) - 1 s for power circuit, 800 A 104 °F (40 °C) - 10 s for power circuit, 400 A 104 °F (40 °C) - 1 min for power circuit, 135 A 104 °F (40 °C) - 10 min for power circuit, 140 A - 100 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 100 A - 1 s for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit |
| Power dissipation per pole | 12.5 W AC-1, 7.2 W AC-3, 7.2 W AC-3e |
| [Ui] rated insulation voltage | Power circuit 1000 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
| Safety reliability level | B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1, B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 4 Mcycles |
| Electrical durability | 1.2 Mcycles 95 A AC-3, 1.3 Mcycles 125 A AC-1, 1.2 Mcycles 95 A AC-3e |
| Control circuit type | AC 50/60 Hz |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.8...1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 50 Hz, 0.85...1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 60 Hz, 0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz, 1...1.1 Uc (131…158 °F (55…70 °C)):operational AC 50/60 Hz |
| Inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)), 245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) |
| Hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)), 26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) |
| Heat dissipation | 6…10 W at 50/60 Hz |
| Operating time | 20...35 ms closing, 6...20 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end, Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible without cable end, Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: flexible without cable end, Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible with cable end, Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) - cable stiffness: flexible with cable end, Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: solid without cable end, Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: solid without cable end |
| Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2, Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm, Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm), Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Mounting Support | Plate, Rail |
| Standards | EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, CSA C22.2 No 14, UL 60947-4-1, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, IEC 60335-1:Clause 30.2 |
|---|---|
| Product Certifications | CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC |
| IP degree of protection | IP20 front face IEC 60529 |
| Protective treatment | THIEC 60068-2-30 |
| Climatic withstand | IACS E10 exposure to damp heat |
| Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C), 140…158 °F (60…70 °C) with derating |
| Operating altitude | 0...9842.52 ft (0...3000 m) |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz), Shocks contactor open 8 Gn for 11 ms), Vibrations contactor closed 3 Gn, 5...300 Hz), Shocks contactor closed 10 Gn for 11 ms) |
| Height | 5 in (127 mm) |
| Width | 3.3 in (85 mm) |
| Depth | 5.1 in (130 mm) |
| Net Weight | 3.55 lb(US) (1.61 kg) |
| Part number | LC1D95G7 |
|---|---|
| Type designation | LC1D |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3389110451269 |
| Warranty (in months) | 18 |
|---|
| Country of origin | CZ |
|---|---|
| Shipping weight | 1.61 kg |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 24 Nov 2026
The rated current of LC1D is 95 A.
The rated operational voltage of LC1D is 1000 V AC.
The rated motor power of LC1D is 45 kW.
The control voltage range of LC1D is 120 V.
The tariff (HS) code on file for LC1D is 853649.
The EAN (GTIN) of LC1D is 3389110451269.
LC1D ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.