- Schneider Electric E125N320FM EasyPact CVS1250N 3P 1250 A 50 kA ETS 2.0 Fixed Moulded Case Circuit Breaker Schneider Electric E125N320FM EasyPact CVS1250N 3P 1250 A 50 kA ETS 2.0 Fixed Moulded Case Circuit Breaker
Schneider Electric E125N320FM EasyPact CVS1250N 3P 1250 A 50 kA ETS 2.0 Fixed Moulded Case Circuit Breaker
Schneider Electric E125N320FM EasyPact CVS1250N 3P 1250 A 50 kA ETS 2.0 Fixed Moulded Case Circuit Breaker
Get Quote
- Description
The Schneider Electric E125N320FM is a 1250 A EasyPact CVS1250N moulded case circuit breaker for low-voltage electrical distribution, built on a medium-to-high breaking N frame. Its ETS 2.0 electronic trip unit gives adjustable long-time overload and instantaneous short-circuit protection (LI), and the 3-pole, 3D frame breaks 50 kA at 380/415 V AC under IEC 60947-2.
Technical Specifications
| SKU / Reference | E125N320FM |
| Brand | Schneider Electric |
| Range | EasyPact CVS1250N |
| Device application | Low-voltage electrical distribution |
| Poles | 3P |
| Protected poles | 3D |
| Rated current [In] | 1250 A at 50 °C |
| Rated operational voltage [Ue] | 440 V AC 50/60 Hz |
| Rated insulation voltage [Ui] | 800 V AC |
| Rated impulse withstand voltage [Uimp] | 8 kV |
| Breaking capacity [Icu] | 70 kA at 220/240 V AC, 50 kA at 380/415 V AC, 45 kA at 440 V AC |
| Service breaking capacity [Ics] | 70 kA at 220/240 V AC, 50 kA at 380/415 V AC, 45 kA at 440 V AC |
| Trip unit | ETS 2.0, electronic |
| Trip unit rating | 1250 A at 50 °C |
| Protection functions | LI (long-time overload + instantaneous short-circuit) |
| Long-time pickup adjustment [Ir] | 0.4...1 x In, adjustable |
| Instantaneous pickup adjustment [Ii] | 1.5...10 x Ir, adjustable |
| Control type | Toggle, rotary handle |
| Mounting | Fixed, backplate support |
| Connection | Front (upside and downside), 70 mm pitch |
| Dimensions (W x H x D) | 210 x 327 x 147 mm |
| Net weight | 14 kg |
| Degree of protection | IP40, IK07 |
| Ambient temperature | -25...70 °C operation, -50...85 °C storage |
| Standards | EN/IEC 60947-2 |
Certifications & Standards
- CCC
- CB
- CE
- EN/IEC 60947-2
Selection Notes
Pick the N frame as the mid-tier option: 50 kA at 380/415 V covers most distribution boards without paying for the H frame's extra breaking capacity. The 3-pole frame protects the three phase conductors only; use it on a balanced three-phase feeder where the neutral is bonded upstream or not distributed. Within the 1250 A CVS1250 frame size, E125N320FM (N class) sits alongside breaking-class siblings at the same amperage -- move up a class if downstream fault studies show higher prospective short-circuit current than 50 kA at 380/415 V, since the ETS 2.0 long-time setting only trims down to 0.4 x In (500 A) and cannot raise the frame's current rating.