- Schneider Electric C11B6TM100B ComPacT NSXm 160B 4P 100 A 25 kA TM-D Fixed Moulded Case Circuit Breaker Schneider Electric C11B6TM100B ComPacT NSXm 160B 4P 100 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C11B6TM100B ComPacT NSXm 160B 4P 100 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C11B6TM100B ComPacT NSXm 160B 4P 100 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Get Quote
- Description
The Schneider Electric C11B6TM100B is a 4P ComPacT NSXm 160B moulded case circuit breaker rated 100 A at 40°C, built on a TM-D thermal-magnetic trip unit with 25 kA breaking capacity (Icu) at 380/415 V AC. This 4P version has protected poles 3D (neutral not protected). It is a fixed-mounting device with front compression lug or busbar connection for low-voltage distribution circuits up to 440 V AC.
| Reference | C11B6TM100B |
| Brand | Schneider Electric |
| Range / Product name | ComPacT NSXm |
| Device short name | NSXm 160B |
| Number of poles | 4P |
| Protected poles | 3D (neutral not protected) |
| [In] Rated current | 100 A at 40°C |
| [Ue] Rated operational voltage | 440 V AC 50/60 Hz |
| [Ui] Rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] Rated impulse withstand voltage | 8 kV |
| [Icu] Rated ultimate breaking capacity | 50 kA at 220/240 V AC, 25 kA at 380/415 V AC, 20 kA at 440 V AC |
| [Ics] Rated service breaking capacity | 50 kA at 220/240 V AC, 25 kA at 380/415 V AC, 20 kA at 440 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI (long-time + instantaneous) |
| [Ir] Long-time pickup adjustment range | 0.7...1 x In |
| [Ii] Instantaneous pickup adjustment range | 1250 A |
| Power dissipation per pole | 7.5 W |
| Control type | Toggle |
| Mounting mode | Fixed |
| Connection terminals | Compression lug/busbar |
| Dimensions (W x H x D) | 108 mm x 137 mm x 80 mm |
| Net weight | 1.42 kg |
| IP degree of protection | IP40 |
| Standards | EN/IEC 60947-2 |
Certifications & Standards
- EN/IEC 60947-2
Selection Notes
Choose the B performance level (25 kA Icu at 380/415 V AC) when the prospective short-circuit current at the installation point stays at or below that rating; move to the higher-breaking-capacity F or N version in the same NSXm frame if the fault-level study gives a different result. The neutral pole is not protected (3D), which fits TN-S boards where neutral overcurrent protection is handled elsewhere. The TM-D trip unit has a fixed long-time delay with pickup adjustable over 0.7...1 x In range and a fixed instantaneous pickup at 1250 A, so downstream coordination relies on current discrimination rather than time grading.