- Description
Schneider Electric's C11B6TM063B is a 4-pole ComPacT NSXm 63B moulded case circuit breaker rated 63 A, delivering 25 kA breaking capacity (Icu) at 415 V AC and a 690 V AC operational voltage (Ue). Its TM-D thermal-magnetic trip unit pairs adjustable overload protection with a fixed 800 A instantaneous short-circuit trip, fixed-mounted for low-voltage distribution boards.
Technical Specifications
| Reference | C11B6TM063B |
| Brand | Schneider Electric |
| Range | ComPacT NSXm |
| Device short name | NSXm 63B |
| Poles | 4P |
| Protected poles | 3D |
| [In] Rated current | 63 A at 40 °C |
| [Ue] Rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| [Ui] Rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] Rated impulse withstand voltage | 8 kV |
| Breaking capacity (Icu) | 50 kA at 220...240 V AC, 25 kA at 380...415 V AC, 20 kA at 440 V AC, 10 kA at 500 V AC |
| Service breaking capacity (Ics) | 50 kA at 220...240 V AC, 25 kA at 380...415 V AC, 20 kA at 440 V AC, 10 kA at 500 V AC |
| Trip unit | TM-D, thermal-magnetic |
| Trip unit protection functions | LI (overload + short-circuit) |
| [Ir] Long-time pick-up adjustment | 0.7...1 x In |
| [Ii] Instantaneous pick-up | 800 A (fixed) |
| Neutral protection | No protection (3D) |
| Earth-leakage protection | Without |
| Control type | Toggle |
| Mounting mode | Fixed |
| Connection terminals | Compression lug/busbar |
| Connection pitch | 35 mm with spreaders, 27 mm without spreaders |
| Dimensions W x H x D | 108 mm x 137 mm x 80 mm |
| Net weight | 1.42 kg |
| IP / IK degree | IP40 / IK07 |
| Ambient temperature (operation) | -25…70 °C |
| Operating altitude | Up to 2000 m without derating, derated up to 5000 m |
| Standards | EN/IEC 60947-2 |
Certifications & Standards
- EN/IEC 60947-2
Selection Notes
The B performance level delivers 25 kA Icu at 380/415 V AC, the compact-frame rating of the ComPacT NSXm range — sized for final distribution circuits rather than incomers. Everlink spring-clamp auxiliary connections and DIN-rail or plate mounting are built in. Its TM-D thermal-magnetic trip unit combines the LI protection set in one block: L is the overload (thermal) function, adjustable 0.7–1 × In, and I is the short-circuit (magnetic) function, fixed at 800 A — so no separate instantaneous relay is needed. The fourth (neutral) pole is unprotected (3D), so a separate neutral overcurrent device is needed if the installation requires neutral protection. Within the same NSXm 63B frame, pick the 63 A trip rating to match the protected circuit's full-load current — lower- and higher-current variants share the same breaking capacity and enclosure footprint.