- Home
- All Products
- Schneider Electric C100H35AFM ComPacT NS1000H 3P 1000 A 70 kA MicroLogic 5.0 A Moulded Case Circuit Breaker Schneider Electric C100H35AFM ComPacT NS1000H 3P 1000 A 70 kA MicroLogic 5.0 A Moulded Case Circuit Breaker
Schneider Electric C100H35AFM ComPacT NS1000H 3P 1000 A 70 kA MicroLogic 5.0 A Moulded Case Circuit Breaker
Schneider Electric C100H35AFM ComPacT NS1000H 3P 1000 A 70 kA MicroLogic 5.0 A Moulded Case Circuit Breaker
Get Quote
- Description
Rated 1000 A with a 70 kA breaking capacity at 380/415 V AC, the C100H35AFM is a 3-pole ComPacT NS1000H moulded case circuit breaker from Schneider Electric. The MicroLogic 5.0 A trip unit delivers overload (L), short-time delayed short-circuit (S) and instantaneous (I) protection, and the device mounts fixed with front connections rated 690 V AC. It also adds an integrated LCD ammeter for local current readout.
Technical Specifications
| Reference | C100H35AFM |
| Brand | Schneider Electric |
| Range of product | ComPacT NS630b...1600 new generation |
| Product or component type | Circuit breaker |
| Number of poles | 3P |
| [In] rated current | 1000 A at 50 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| Breaking capacity (Icu) | 85 kA at 220/240 V AC, 70 kA at 380/415 V AC, 65 kA at 440 V AC, 50 kA at 500/525 V AC, 42 kA at 660/690 V AC, conforming to IEC 60947-2 |
| Rated service breaking capacity (Ics) | 52 kA at 220/240 V AC, 52 kA at 380/415 V AC, 48 kA at 440 V AC, 37 kA at 500/525 V AC, 31 kA at 660/690 V AC, conforming to IEC 60947-2 |
| [Icw] rated short-time withstand current | 19.2 kA for 1 s |
| Utilisation category | Category B |
| Suitability for isolation | Yes, conforming to EN/IEC 60947-2 |
| Trip unit name | MicroLogic 5.0 A |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSI (overload (L), short-time delayed short-circuit (S) and instantaneous (I) protection) |
| [Ir] long-time pick-up adjustment range | 0.4...1 x In, adjustable, 9 settings |
| [Isd] short-time pick-up adjustment range | 1.5...10 x Ir, adjustable, 9 settings |
| [Ii] instantaneous pick-up adjustment range | Off, or 2...15 x In |
| Earth-leakage protection | Without |
| Zone selective interlocking (ZSI) | With |
| Display / measurement | LCD display, ammeter |
| Control type | Manually operated |
| Mounting mode | Fixed, backplate-mounted |
| Connection (upside / downside) | Front / Front |
| Dimensions (W x H x D) | 210 x 327 x 147 mm |
| Net weight | 14 kg |
| IP / IK degree of protection | IP40 / IK07 |
Certifications & Standards
- IECEE CB Scheme
- EN/IEC 60947-2
Selection Notes
The MicroLogic 5.0 A trip unit on the C100H35AFM is configured for overload (L), short-time delayed short-circuit (S) and instantaneous (I) protection. Adding the S (short-time delay) stage to L-I lets this trip unit hold off tripping briefly on a downstream fault, so an upstream breaker can coordinate selectively with devices further down the circuit. In the NS1000 case size, this H-frame breaker is the high breaking capacity option (70 kA Icu at 380/415 V AC); the L-frame (150 kA Icu) and the N-frame (50 kA Icu) versions share the same case and accessories but trade breaking capacity for cost or vice versa. Within the same frame, the plain (no-suffix) trip unit drops the ammeter if local current readout isn't needed, while the E-suffix version swaps it for an energy meter. As a 3-pole unit it protects the three phases only; the 4-pole version of the same frame adds switched or protected neutral handling.