Part number
C080N360FM
$1,800.73 On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric C080N360FM ComPacT NS800N 3P 800 A 50 kA MicroLogic 6.0 Moulded Case Circuit Breaker

Schneider Electric C080N360FM ComPacT NS800N 3P 800 A, 50 kA Icu, MicroLogic 6.0 trip unit.

Rated current
800 A
Rated operational voltage
690 V AC
Poles
3P
Description

About the C080N360FM

The Schneider Electric C080N360FM is a 3-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380/415 V AC and a 690 V AC operational voltage. It carries the MicroLogic 6.0 trip unit for overload (L), short-time delayed short-circuit (S), instantaneous (I) and ground-fault (G) protection, and mounts fixed with front-connected upstream and downstream terminals.

Certifications & Standards

  • IECEE CB Scheme
  • EN/IEC 60947-2

Selection Notes

The MicroLogic 6.0 trip unit on the C080N360FM is configured for overload (L), short-time delayed short-circuit (S), instantaneous (I) and ground-fault (G) protection. Stacking G (ground-fault) on top of L-S-I gives this trip unit adjustable earth-fault tripping as well as time-graded short-circuit discrimination, useful on solidly grounded systems that would otherwise need a separate earth-fault relay. In the NS800 case size, this N-frame breaker is the standard breaking capacity option (50 kA Icu at 380/415 V AC); the H-frame (70 kA Icu) and the L-frame (150 kA Icu) versions share the same case and accessories but trade breaking capacity for cost or vice versa. The A- and E-suffix trip units in the same frame add an ammeter or energy meter respectively, for installations that want local metering without extra hardware. As a 3-pole unit it protects the three phases only; the 4-pole version of the same frame adds switched or protected neutral handling.

Specification

Full specification

90 values · Last verified 30 Oct 2026

Main 20

Range ComPacT
Product name ComPacT NS new generation
Range of product ComPacT NS630b...1600 new generation
Product or component type Circuit breaker
Device application Distribution
Number of poles 3P
Protected poles description 3D
[In] rated current 800 A at 50 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category B
Breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code N 50 kA 415 V AC
Trip unit name MicroLogic 6.0
Trip unit technology Electronic
Trip unit protection functions LSIG
Control type Manually operated
Mounting mode Fixed

Complementary 36

[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity 50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current 19.2 kA 1 s conforming to IEC 60947-2
Mechanical durability 10000 cycles
Electrical durability 2000 cycles at 690 V In, 4000 cycles at 690 V In/2, 5000 cycles at 440 V In, 6000 cycles at 440 V In/2
Power losses 15 W
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 70 mm
Protection type L : for overload protection (long time), S : for short time short-circuit protection, I : for instantaneous short-circuit protection, G : for ground fault protection
Trip unit rating 800 A at 50 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 0.4...1 x In
Long-time protection delay adjustment type tr Adjustable 9 settings
[tr] long-time delay adjustment range 12.5…600 s at 1.5 x Ir, 0.5…24 s at 6 x Ir, 0.7…16.6 s at 7.2 x Ir
Thermal memory 20 mn
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] short-time delay adjustment range 0.1…0.4 s I²t=on, 0…0.4 s I²t=off
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range Off, 2...15 x In
Ground-fault protection pick-up adjustment type Ig Adjustable 9 settings
[Ig] ground-fault pick-up adjustment range 0.3...1 x In for In <= 400 A, 0.2...1 x In for 400 A < In < 1250 A, 500...1200 A for In >= 1250 A
Ground-fault protection time delay adjustment type tg Adjustable
[tg] Ground-fault time delay adjustment range 0.1…0.4 s I²t=on, 0…0.4 s I²t=off
Earth-leakage protection Without
Zone selective interlocking ZSI Without
Auxiliary contact composition 1 NO/NC
Local signalling 4 LEDs (red) for fault indication, 1 LED (yellow) for overload
Width (W) 210 mm
Height (H) 327 mm
Depth (D) 147 mm
Net weight 14 kg

Environment 11

Standards EN/IEC 60947-2
Product certifications IECEE CB Scheme
Overvoltage category III
Electrical shock protection class Class II on front face
Pollution degree 3 conforming to IEC 60947
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating, 2000 m...5000 m with derating
Show all 90 specifications ↓ Show less ↑23 more values in Identification, Contractual warranty, Logistics.

Identification 6

Part number C080N360FM
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production

Contractual warranty 1

Warranty (in months) 18

Logistics 16

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 23.000 cm
Package 1 Width 37.000 cm
Package 1 Length 39.500 cm
Package 1 Weight 11.816 kg
Unit Type of Package 2 P12
Number of Units in Package 2 4
Package 2 Height 45.000 cm
Package 2 Width 80.000 cm
Package 2 Length 120.000 cm
Package 2 Weight 61.260 kg
Shipping weight 14.0 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for C080N360FM

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CB Scheme
  • EN/IEC 60947-2
Quick answers

Questions about the C080N360FM

What is the rated current of C080N360FM?

The rated current of C080N360FM is 800 A.

Which supply voltage is C080N360FM rated for?

The rated operational voltage of C080N360FM is 690 V AC.

What is the HS code of C080N360FM for customs?

The tariff (HS) code on file for C080N360FM is 853620.

Where does C080N360FM ship from, and how fast?

C080N360FM ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for MCCB

All guides for MCCB
Reviews

Customer reviews

Series

Schneider Electric Schneider ComPacT NS

Brand
Schneider Electric
Series
Schneider ComPacT NS
Series page →
Series

Other series in Molded Case Circuit Breakers (MCCB)

$1,800.73 On request
Get a Quote
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · C080N360FM

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart