- Home
- Schneider Altistart Soft Starters
- Schneider Electric ATS490D17Y Altivar ATS490 17A 208-690V AC 7.5 kW Soft Starter Schneider Electric ATS490D17Y Altivar ATS490 17A 208-690V AC 7.5 kW Soft Starter
Schneider Electric ATS490D17Y Altivar ATS490 17A 208-690V AC 7.5 kW Soft Starter
Schneider Electric ATS490D17Y Altivar ATS490 17A 208-690V AC 7.5 kW Soft Starter
Get Quote
- Description
The Schneider Electric ATS490D17Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 17 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 7.5 kW at 400 V (5.5 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP/EtherNet/IP port support supervised, cybersecure motor control from the same enclosure.
Technical Specifications
| Reference | ATS490D17Y |
| GTIN | 3606486948750 |
| Brand | Schneider Electric |
| Range of Product | Altivar Soft Starter ATS490 |
| Product Type | Soft starter |
| Phase | 3 phase |
| Supply Voltage (Ue) | 208...690 V AC (-15...+10%) |
| Supply Frequency | 50...60 Hz |
| Rated Operational Current – Normal Duty (Ie) | 17 A at 40 °C |
| Rated Operational Current – Heavy Duty | 12 A at 40 °C |
| Motor Power at 400 V – Normal Duty | 7.5 kW |
| Motor Power at 400 V – Heavy Duty | 5.5 kW |
| Control Circuit Voltage (Us) | 110...230 V AC, 50/60 Hz |
| Control Circuit Voltage (Uc) | 24 V DC |
| Apparent Power | 70 VA |
| IP Degree of Protection | IP20 |
| Safe Torque Off (STO) | SIL 1 (IEC 61508), PL c / Category 2 (ISO 13849) |
| Communication | Modbus serial, Modbus TCP/EtherNet/IP |
| Discrete Inputs / Relay Outputs | 5 digital inputs, 3 relay outputs, 2 digital outputs |
| Rated Insulation Voltage (Ui) | 690 V |
| Dimensions (W x D x H) | 160 x 185 x 283 mm |
| Net Weight | 4 kg |
Certifications & Standards
- CE
- cULus
- UKCA
- RCM
- CCC
- DNV
- ATEX
- EAC
- KC
- EN/IEC 60947-4-2
- UL 60947-4-2
- IEC 60664-1
Selection Notes
At 17 A normal duty, the ATS490D17Y sits at the entry end of the ATS490 frame and covers motors up to 7.5 kW at 400 V without stepping up to a larger enclosure. Choose the heavy-duty rating (12 A) instead of the normal-duty figure when the load cycles frequently or starts against high inertia, since it keeps the same 400% Ie / 13 s overload margin with a lower continuous current. Applications with variable or quadratic torque, such as pumps, fans, compressors and conveyors, fit the normal-duty rating; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. For motors above 7.5 kW at 400 V, move up to the next current frame in the ATS490 range.