The Schneider Electric METSEPM5760 is a PowerLogic PM5760 flush-mount power meter combining waveform capture with sag/swell detection and residual current monitoring on the PM5560 base platform. It delivers Class 0.2S accuracy to IEC 62053-22 at 128 samples per cycle, measures voltage, current, power, energy and harmonics to the 63rd order, and monitors neutral current directly with calculated ground current.
Technical Specifications
| Reference | METSEPM5760 |
| Brand | Schneider Electric |
| Range | PowerLogic PM5000 |
| Device Short Name | PM5760 |
| Accuracy Class | Class 0.2S active energy (IEC 62053-22) |
| Power Quality Analysis | Up to the 63rd harmonic, waveform capture, sag/swell detection, residual current monitoring |
| Sampling Rate | 128 samples/cycle |
| Rated Supply Voltage (Us) | 90-528 V AC 45-65 Hz / 100-300 V DC |
| Rated Current Input (In) | 1 A or 5 A |
| Network Type | 1P+N, 3P, 3P+N |
| Measurement Voltage | 20-400 V AC phase-neutral / 20-828 V AC phase-phase |
| Metering Type | Measured neutral current, calculated ground current, residual current I0 |
| Digital Inputs | 4, WAGES-capable |
| Digital Outputs | 2 |
| Alarms | 52 configurable |
| Communication | RS485 Modbus RTU/ASCII; 2 x Ethernet RJ45, Modbus TCP/IP, BACnet/IP, DNP3 |
| Memory Capacity | 1.1 MB |
| Display | Monochrome graphic LCD, 128 x 128 px |
| Mounting | Flush-mounted, 96 x 96 mm |
| IP Rating | IP30 rear / IP54 display |
| Dimensions (W x D x H) | 96 x 72 x 96 mm |
| Weight | 0.45 kg |
Certifications & Standards
- CE
- cULus
- EN 50470-1
- EN 50470-3
- IEC 61557-12
- IEC 62053-22
- ANSI C12.20
Selection Notes
The PM5760 is the top of the PM5000 flush-mount line, combining the PM5650's waveform capture and sag/swell detection with the PM5660's residual current monitoring in a single meter. It is the right choice for incoming feeders and critical loads where both power-quality disturbance analysis and ground-fault trending are needed from one device, avoiding a second meter or external relay. Where only one of the two functions is required, the PM5650 or PM5660 covers it at the same base price point.