- Home
- Power Quality, Metering & Power Supplies
- Schneider Electric METSEPM5660 PowerLogic PM5660 Residual Current Monitoring Class 0.2S 63rd Power Meter Schneider Electric METSEPM5660 PowerLogic PM5660 Residual Current Monitoring Class 0.2S 63rd Power Meter
Schneider Electric METSEPM5660 PowerLogic PM5660 Residual Current Monitoring Class 0.2S 63rd Power Meter
Schneider Electric METSEPM5660 PowerLogic PM5660 Residual Current Monitoring Class 0.2S 63rd Power Meter
Get Quote
- Description
The Schneider Electric METSEPM5660 is a PowerLogic PM5660 flush-mount power meter that adds residual current monitoring with ground current calculation to the PM5560 base platform. It delivers Class 0.2S accuracy to IEC 62053-22 at 128 samples per cycle, measures voltage, current, power, energy and harmonics to the 63rd order, and monitors neutral current directly.
Technical Specifications
| Reference | METSEPM5660 |
| Brand | Schneider Electric |
| Range | PowerLogic PM5000 |
| Device Short Name | PM5660 |
| Accuracy Class | Class 0.2S active energy (IEC 62053-22) |
| Power Quality Analysis | Up to the 63rd harmonic, residual current monitoring |
| Sampling Rate | 128 samples/cycle |
| Rated Supply Voltage (Us) | 90-528 V AC 45-65 Hz / 100-300 V DC |
| Rated Current Input (In) | 1 A or 5 A |
| Network Type | 1P+N, 3P, 3P+N |
| Measurement Voltage | 20-400 V AC phase-neutral / 20-828 V AC phase-phase |
| Metering Type | Measured neutral current, calculated ground current, residual current I0 |
| Digital Inputs | 4, WAGES-capable |
| Digital Outputs | 2 |
| Alarms | 52 configurable |
| Communication | RS485 Modbus RTU/ASCII; 2 x Ethernet RJ45, Modbus TCP/IP, BACnet/IP, DNP3 |
| Memory Capacity | 1.1 MB |
| Display | Monochrome graphic LCD, 128 x 128 px |
| Mounting | Flush-mounted, 96 x 96 mm |
| IP Rating | IP30 rear / IP54 display |
| Dimensions (W x D x H) | 96 x 72 x 96 mm |
| Weight | 0.45 kg |
Certifications & Standards
- CE
- cULus
- EN 50470-1
- EN 50470-3
- IEC 61557-12
- IEC 62053-22
- ANSI C12.20
Selection Notes
The PM5660 adds residual current (I0) monitoring to the PM5560 base, calculating a ground-fault indication from the measured phase and neutral currents without a separate core-balance CT. That makes it suited to feeders where early insulation-degradation or earth-leakage trending matters more than waveform disturbance analysis. Where sag/swell waveform capture is the priority instead, the PM5650 covers that function on the same base platform; the PM5760 combines both.