The Siemens 6ES7222-1XF32-0XB0 is a SIMATIC S7-1200 SM 1222 digital output module with 8 relay changeover-contact outputs rated 2 A each, switching 5-30 V DC or 5-250 V AC loads directly. It draws its logic supply from the S7-1200 backplane bus at 20.4-28.8 V DC, adding 140 mA of 5 V DC backplane load and 5 W of power loss.
Technical Specifications
| SKU | 6ES7222-1XF32-0XB0 |
| Brand | Siemens |
| Series | SIMATIC S7-1200 |
| Product type designation | SM 1222, DQ 8x relay/2 A |
| Supply voltage, permissible range | 20.4-28.8 V DC (backplane bus) |
| Current consumption from backplane bus, max. | 140 mA |
| Power loss, typ. | 5 W |
| Digital outputs | 8, relay changeover contact |
| Output voltage (DC) | 5-30 V DC |
| Output voltage (AC) | 5-250 V AC |
| Output current, rated (signal 1) | 2 A |
| Switching capacity, resistive load, max. | 2 A |
| Switching capacity, inductive load, max. | 2 A |
| Switching capacity, lamp load, max. | 30 W DC / 200 W AC |
| Relay operating cycles, max. | 10 million mechanical, 100000 at rated load |
| Cable length, shielded / unshielded, max. | 500 m / 150 m |
| IP degree of protection | IP20 |
| Dimensions (W x H x D) | 70 x 100 x 75 mm |
| Weight, approx. | 310 g |
Certifications & Standards
- CE
- CSA
- UL
- cULus
- FM
- RCM
- KC
- Marine
Selection Notes
The changeover (SPDT) relay contacts switch AC or DC loads directly from the CPU without an external interposing relay, but short-circuit protection is not built in, so size external fusing or a circuit breaker to the 2 A rated current per channel. Relay life is rated at 10 million mechanical cycles but drops to 100000 at rated load current, so for high-cycle switching duty a solid-state output module is the better fit; choose this relay variant when the load is AC, mixed AC/DC, or exceeds the voltage range of transistor outputs.
Applications
Fits applications that need a PLC output stage to switch mains-referenced loads directly: contactor coils, indicator lamps, small solenoid valves, and mixed 24 V DC / 230 V AC control panels where isolating relay contacts avoid mixing supply domains on one output card.