- Home
- Connection Modules & Cables
- Siemens 6ES7924-2AA20-0BC0 SIMATIC TOP Connect TP1 32-Channel Push-In PLC Connection Module Siemens 6ES7924-2AA20-0BC0 SIMATIC TOP Connect TP1 32-Channel Push-In PLC Connection Module
Siemens 6ES7924-2AA20-0BC0 SIMATIC TOP Connect TP1 32-Channel Push-In PLC Connection Module
Siemens 6ES7924-2AA20-0BC0 SIMATIC TOP Connect TP1 32-Channel Push-In PLC Connection Module
Get Quote
- Description
The Siemens 6ES7924-2AA20-0BC0 is a SIMATIC TOP connect TP1 connection module with 32 channels and push-in terminals with LED status indication, built for wiring SIMATIC S7-1500 digital I/O modules. It handles up to 1A per pin and 2A total current at 24V DC, and is rated ATEX, IECEx and UKEX for use in hazardous areas.
Technical Specifications
| SKU | 6ES7924-2AA20-0BC0 |
| Brand | Siemens |
| Series | SIMATIC TOP connect |
| Target system | SIMATIC S7-1500 |
| Suitability | Digital I/O modules |
| Operating voltage | 24 V DC, max. 28.8 V |
| Ampacity per pin, max. | 1 A |
| Continuous current per signal cable, max. | 1 A |
| Total current, max. | 2 A |
| Number of channels | 32 |
| Number of terminals | 48 (32 I/O; 8 L+, 8 M) |
| Terminal type | Push-in, top position |
| Status display | LED yellow per channel, active high; green power LED for 24V DC OK |
| Field-side connector | 50-pole IDC connector with strain relief |
| Conductor cross-section | 0.2-2.5 mm2 (stranded, flexible, with or without ferrule) |
| Wire length, max. | 30 m between front connector module and connection module |
| Mounting | DIN rail 35 mm or 15 mm, any position |
| Dimensions (W x H x D) | 100 x 76 x 60 mm |
| Ambient temperature, operation | 0 to 60 degC |
| Ambient temperature, storage | -40 to +70 degC |
| Overvoltage category / pollution degree | 2 / 2 |
| Enclosure color | Grey |
| Weight | 0.21 kg |
Certifications & Standards
- cULus
- IECEx
- ATEX
- ULhazloc
- UKEX
- CCC-Ex
- EEx e
- Environmental Product Declaration
Selection Notes
The 32-channel push-in design with a per-channel LED lets a technician see which I/O point is energized without a multimeter, which speeds up commissioning and fault-finding on a fully wired S7-1500 digital I/O rack. The 50-pole IDC field connector and 30m maximum wire length between the front connector module and this connection module fits point-to-point cabinet wiring rather than long field runs. With ATEX, IECEx and UKEX Zone ratings alongside cULus, this module is one of the few TOP connect parts qualified for use on the panel side of a hazardous-area installation, not just a general-purpose industrial cabinet.
Applications
Fully modular field wiring for SIMATIC S7-1500 digital I/O in machine and process control panels, including panels installed in ATEX/IECEx/UKEX Zone 2 hazardous areas.