Motor Protection Circuit Breakers (MPCB)
319 parts
Motor protection circuit breakers (MPCB) from ABB, Siemens and Schneider Electric combine short-circuit and overload protection for motor feeders. The range covers 0.16 A to 500 A in 3-pole versions, from small manual starters to large thermal-magnetic breakers. Stoklink ships worldwide from Turkey and quotes project volumes on request.
3RV2041-4RA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2041-4MA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2041-4KA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2041-4JA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2031-4XA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2031-4WA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2031-4VA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2031-4UA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2031-4RA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2031-4KA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2031-4JA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4PA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4NA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4NA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4FA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4EA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4EA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4DA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4CA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4CA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4BA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4BA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4AA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2021-4AA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-4AA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-4AA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1KA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1KA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1JA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1JA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1HA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1HA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1GA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1GA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1FA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1FA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1EA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1EA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1DA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1DA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1CA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1CA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1BA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1BA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-1AA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-0KA20 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
3RV2011-0KA10 3RV2Siemens · 3RV2 10A 3P 690V Motor Protection Circuit Breaker
Can't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
Motor Protection Circuit Breakers (MPCB) buying guide
What's in this range
- Siemens SIRIUS 3RV2 and 3RV1 breakers, plus 3RN2 versions for motor protection with thermistor evaluation.
- Schneider Electric TeSys Deca GV2 and GV3 manual starters, TeSys GV4 thermal-magnetic breakers and Easy TeSys Power.
- ABB MS116, MS132 and MS165 manual motor starters and MO132 magnetic-only breakers.
- Accessories such as auxiliary contacts, busbar adapters and trip indicators for the 3RV1935 and GV2 families.
How to choose
- Setting range. The motor full-load current should sit inside the adjustable thermal band.
- Breaking capacity at the supply voltage, in kA, against the prospective short-circuit current.
- Thermal-magnetic or magnetic-only. Magnetic-only breakers need a separate overload relay.
- Coordination with the contactor, type 1 or type 2 under IEC 60947-4-1.
- Frame size and mounting: DIN rail or busbar system.
Motor Protection Circuit Breakers (MPCB) questions
What is the difference between an MPCB and an MCCB?
An MPCB is built around motor starting currents, with an adjustable thermal band and a magnetic trip set for inrush. An MCCB is a general feeder breaker with a wider rating scale.
Does an MPCB replace the overload relay?
Yes, when it has a thermal release. Magnetic-only types such as the ABB MO132 do not, so they need an overload relay downstream.
Do you export MPCBs outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.