- Home
- Motor Control & Protection
- Schneider Electric TPRST038 TeSys Island TPRST 38A AC-3 18.5kW DOL Motor Starter Module Schneider Electric TPRST038 TeSys Island TPRST 38A AC-3 18.5kW DOL Motor Starter Module
Schneider Electric TPRST038 TeSys Island TPRST 38A AC-3 18.5kW DOL Motor Starter Module
Schneider Electric TPRST038 TeSys Island TPRST 38A AC-3 18.5kW DOL Motor Starter Module
Get Quote
- Description
The Schneider Electric TPRST038 is a TeSys island motor starter rated 38 A at AC-3 for direct-on-line control of motors up to 18.5 kW at 400 V (40 A at AC-1, up to 690 V). Connected through a TPRBC bus coupler, it provides thermal overload, phase-loss, phase-unbalance, and ground-current protection with a 0.76-38 A adjustable thermal setting.
Technical Specifications
| Reference | TPRST038 |
| GTIN | 3606489832766 |
| Brand | Schneider Electric |
| Range | TeSys Island |
| Product type | Motor starter |
| Motor starter type | Direct on line |
| Poles | 3P, 3 NO |
| Utilisation category | AC-1, AC-2, AC-3, AC-4, AC-3e |
| Rated operational current [Ie] | 38 A at AC-3 / 40 A at AC-1 (<=440 V) |
| Motor power (AC-3) | 18.5 kW at 380-415/440/500/690 V; 9 kW at 230 V |
| Rated operational voltage [Ue] | Up to 480 V (cat. III) / up to 690 V (cat. II) |
| Rated insulation voltage [Ui] | 690 V IEC / 600 V UL-CSA |
| Thermal protection adjustment range | 0.76-38 A |
| Rated breaking capacity | 550 A at 440 V |
| Rated short-time withstand current [Icw] | 430 A / 1 s, 310 A / 10 s at 40 C |
| Control circuit voltage [Uc] | 24 V DC, supplied by the bus coupler |
| Mounting mode | 35 mm symmetrical DIN rail |
| Net weight | 0.718 kg |
| Dimensions (W x D x H) | 45 x 115 x 121 mm |
| IP degree of protection | IP20 |
| Ambient operating temperature | -10 to 50 C without derating |
Certifications & Standards
- CCC
- EAC
- UL
- CSA
- EN/IEC 60947-1
- EN/IEC 60947-4-1
- UL 60947-4-1
- CSA C22.2 No 60947-4-1
Selection Notes
At 38 A AC-3 / 18.5 kW, the TPRST038 covers mid-range motor loads within the TeSys island starter line. Its overvoltage category steps down from III to II above 480 V, so at the full 690 V rating the installation needs the corresponding category-II coordination rather than the tighter cat.-III clearances used below 480 V. The 0.76-38 A adjustable thermal range and 430 A / 1 s short-time withstand current cover motor starting current without a separate overload relay, provided the upstream device is coordinated for that let-through. Move up to a higher-current island starter when the motor's full-load current exceeds 38 A at AC-3.