CAD50ED is Schneider Electric's TeSys Deca control relay in a 5NO arrangement, built around a 48 V DC coil and a 140 A AC rated making capacity for up to 690 V circuits. Rated for AC-15/DC-13 duty between -40 and +60 °C, it duplicates and interlocks pilot signals in motor control circuits, terminating on screw clamp terminals on DIN rail or a mounting plate.
Technical Specifications
| Reference | CAD50ED |
| Brand | Schneider Electric |
| Range | TeSys Deca |
| Product Type | Control Relay |
| Pole Contact Composition | 5NO |
| Utilisation Category | AC-14 / AC-15 / DC-13 |
| Rated Operational Voltage (Ue) | ≤690 V AC (25–400 Hz) |
| Control Circuit Voltage (Uc) | 48 V DC |
| Conventional Thermal Current (Ith) | 10 A (at 60 °C) |
| Rated Making Capacity (Irms) | 140 A AC / 250 A DC (IEC 60947-5-1) |
| Rated Short-Time Withstand Current (Icw) | 100 A - 1 s / 120 A - 500 ms / 140 A - 100 ms |
| Rated Insulation Voltage (Ui) | 690 V (IEC 60947-5-1) / 600 V (UL, CSA) |
| Control Circuit Voltage Limits | drop-out 0.1–0.25 Uc, operational 0.7–1.25 Uc (≤60 °C) |
| Maximum Operating Rate | 180 cyc/min |
| Inrush / Hold-in Power | 5.4 W / 5.4 W (20 °C) |
| Mounting | 35 mm DIN rail or screw-fixed mounting plate |
| Connections | Screw clamp terminals, 1–4 mm² |
| Dimensions (H × W × D) | 77 × 45 × 93 mm (H × W × D) |
| Net Weight | 0.58 kg |
| IP Degree of Protection | IP2X (front face) |
| Ambient Temperature | -40…+60 °C operation (to 70 °C with derating), -60…+80 °C storage |
Certifications & Standards
- CE
- UKCA
- UL
- CSA
- CCC
- EAC
- IEC 60947-5-1
Selection Notes
Choose this 5NO variant for five make contacts, useful where one command must be duplicated to several downstream circuits without a break contact. The 48 V DC coil matches circuits already wired at that voltage, avoiding a separate step-down winding. The DC coil carries no steady-state inrush surge but closes in 53–72 ms — noticeably slower than the AC-coil variant's 12–22 ms — because of the electronic surge-limiting circuit; account for that when the relay is in a fast-cycling sequence.