The Schneider Electric RM22UA33MR is a Harmony RM22-UA single-phase voltage control relay, measuring a 15-500 V AC/DC signal for overvoltage or undervoltage conditions in window mode while powered from a 24-240 V AC/DC supply. It switches two 8 A changeover contacts in a 22.5 mm wide DIN rail housing with a front diagnostic button.
Technical Specifications
| Reference | RM22UA33MR |
| Brand | Schneider Electric |
| GTIN | 3606480792250 |
| Range of Product | Harmony Control Relays |
| Relay Name | RM22UA |
| Relay Type | Voltage control relay |
| Phase | 1 phase |
| Relay Monitored Parameters | Undervoltage/overvoltage in window mode, over/undervoltage detection |
| Control Type | With test button |
| [Us] Rated Supply Voltage | 24-240 V AC/DC, 50/60 Hz, non self-powered |
| Measurement Range | 15-500 V AC/DC |
| Time Delay Type | Adjustable 0.1-30 s, +/- 10% of full scale |
| Output Contacts | 2 C/O |
| Nominal Output Current | 8 A |
| Switching Capacity | 2000 VA |
| Response Time | <= 500 ms |
| IP Degree of Protection | IP20 terminals, IP40 housing, IP50 front panel |
| Mounting Support | 35 mm DIN rail |
| Width | 0.9 in (22.5 mm) |
| Net Weight | 0.24 lb(US) (0.11 kg) |
Certifications & Standards
- RCM
- UL
- EAC
- CSA
- CE
- GL
- CCC
- IEC 60255-1
Selection Notes
The 15-500 V measurement range on RM22UA33MR covers mains-level single-phase circuits directly, where the 1-100 V RM22UA32MR sibling would need a voltage divider ahead of it. Both parts share the same 24-240 V AC/DC supply, 2 C/O 8 A output and 22.5 mm housing, so the choice between them depends only on whether the monitored signal is a low-voltage sensor output or a line-level circuit - specify the RM22UA33MR directly on 110 V, 230 V or similar single-phase supplies without additional signal conditioning. Reliability data rates the RM22UA family at B10d = 290,000 operations and an MTTFd of 308.2 years, consistent across the 1-100 V and 15-500 V measurement-range variants since the output stage and mechanical contacts are shared hardware.