- Home
- All Collections
- Low Voltage Fuse Links (NH, BS88, Cylindrical)
Low Voltage Fuse Links (NH, BS88, Cylindrical)
Siemens 3NA6807 3NA6 20A 500V Fuse
Siemens 3NA6805 3NA6 16A 500V Fuse
Siemens 3NA6804 3NA6 4A 500V Fuse
Siemens 3NA6803 3NA6 10A 500V Fuse
Siemens 3NA6802 3NA6 2A 500V Fuse
Siemens 3NA6801 3NA6 6A 500V Fuse
Siemens 3NA6260 3NA6 400A 500V Fuse
Siemens 3NA6252 3NA6 315A 500V Fuse
Siemens 3NA6250 3NA6 300A 500V Fuse
Siemens 3NA6244 3NA6 250A 500V Fuse
Siemens 3NA6240 3NA6 200A 500V Fuse
Siemens 3NA6144 3NA6 250A 500V Fuse
Siemens 3NA6140 3NA6 200A 500V Fuse
Siemens 3NA6136 3NA6 160A 500V Fuse
Siemens 3NA6132 3NA6 125A 500V Fuse
Siemens 3NA6130 3NA6 100A 500V Fuse
Siemens 3NA6124 3NA6 80A 500V Fuse
Siemens 3NA3836-8 3NA3 160A 400V Fuse
Siemens 3NA3836 3NA3 160A 500V Fuse
Siemens 3NA3832-8 3NA3 125A 400V Fuse
Low voltage fuse links from Siemens, Mersen, ABB and Schneider Electric cover NH, BS88 and cylindrical formats from 0.5 A to 1250 A. The range holds over 450 products, including Siemens 3NA3 and 3NA6, Mersen DIN CNN and BS88 links, and ABB OFAF links. Stoklink ships worldwide from Turkey on EXW terms, and quotes for project volumes are available on request.
What's in this range
- NH fuse links such as Siemens 3NA3 and 3NA6 and ABB OFAF for panel and feeder protection.
- BS88 links, including feeder pillar gU types at 415 VAC.
- Cylindrical ferrule links, for example 10x38 gG types rated 400 to 690 VAC.
- UL and DIN CNN and CNL blade fuses for North American and DIN-style equipment.
- Siemens 3NP1 and 3NW6 series fuse parts for fuse switch and holder systems.
How to choose
- Operating class: gG protects cables, aM protects motor circuits and tolerates starting current.
- Rated current and voltage: select from the load current and the line voltage, such as 400, 500 or 690 VAC.
- Size: NH00 to NH4, BS88 or 10x38 must fit the base or holder you already have.
- Breaking capacity: compare it with the prospective short-circuit current, typically stated in kA on the datasheet.
- Standard: IEC 60269 for NH and cylindrical links, BS 88 for British Standard types.
FAQ
What does gG mean on a fuse link?
gG is a full-range, general-purpose class under IEC 60269. It clears both overloads and short circuits, so it protects cables and general loads.
Are NH and BS88 fuses interchangeable?
No. The dimensions and contact systems differ, so a BS88 link does not fit an NH base. Match the link to the base or holder size.
How are orders shipped?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and quotes for larger quantities are available.