- Home
- DC UPS & Buffer Modules
- Siemens 6EP1935-6MF01 SITOP Battery Module 24V 12Ah Maintenance-Free DC UPS Module Siemens 6EP1935-6MF01 SITOP Battery Module 24V 12Ah Maintenance-Free DC UPS Module
Siemens 6EP1935-6MF01 SITOP Battery Module 24V 12Ah Maintenance-Free DC UPS Module
Siemens 6EP1935-6MF01 SITOP Battery Module 24V 12Ah Maintenance-Free DC UPS Module
Get Quote
- Description
The Siemens 6EP1935-6MF01 is a SITOP battery module with 24 V/12 Ah maintenance-free sealed lead-acid batteries, built to extend runtime on the SITOP DC UPS modules rated 6 A, 15 A and 40 A. It delivers up to 30 A in buffering mode and up to 30 A peak current, with a 20 A/32 V battery fuse for short-circuit protection and a maximum 3 A charging current.
Technical Specifications
| Order Number | 6EP1935-6MF01 |
| Brand | Siemens |
| Series | SITOP battery |
| Product Designation | Battery module 12 Ah |
| Battery Type | Maintenance-free lead-acid batteries |
| Battery Capacity | 12 A.h |
| Output Voltage | 24 V DC |
| Output Current in Buffering Mode (max) | 30 A |
| Peak Current | 30 A |
| Charging Current (max) | 3 A |
| End-of-Charge Voltage at 20 degC | 27.3 V |
| Short-Circuit Protection | Battery fuse 20 A/32 V |
| Overload Protection | Valve control |
| Protection Class IP | IP00 |
| Operating Resource Protection Class | Class III |
| Ambient Temperature (Operation) | -15 ... +50 degC |
| Ambient Temperature (Storage) | -20 ... +50 degC |
| Service Life at 20 degC (typical) | 4 years |
| Service Life at 30 degC (typical) | 2 years |
| Enclosure Dimensions (W x H x D) | 253 x 168 x 121 mm |
| Fastening Method | Wall mounting, keyhole for M4 screws |
| Number of Cells | 12 |
| Net Weight | 9 kg |
| Country of Origin | AT |
Certifications & Standards
- CE
- EAC
- Shipbuilding
- ABS
- DNV
- EPD
Selection Notes
This 12 Ah battery pairs with SITOP DC UPS modules across the 6 A, 15 A and 40 A range - verify buffering runtime against the connected UPS module's load rather than this module's 30 A output-current ceiling, which is a maximum, not a guaranteed runtime figure. The 20 A/32 V battery fuse and Class III protection rating fix the safety boundary for the pack itself, and wall or flat-surface keyhole mounting keeps the 9 kg pack out of the UPS module's own footprint. Service life drops from 4 years at 20 degC to 2 years at 30 degC, so ambient temperature at the installation site is the main variable to check before setting replacement intervals.
Applications
Used as the battery back-up stage in SITOP DC UPS installations protecting PLCs, drives and control panels through mains interruptions, where the 6 A, 15 A or 40 A UPS module handles power management and this module supplies the stored 24 V DC energy.