Filter

Contactors

Filter
Showing 1 - 760 of 973 items

Schneider Electric LC1E3810BD Easy TeSys Contactor 3P 3NO AC-3 38 A ≤440V 24V DC Coil 1NO Contactor

Reference No: LC1E3810BD
Catalog No: LC1E3810BD
Rated Current (A): 38
Rated Voltage (VAC): 24 V DC
Number of Poles: 3P
0 pcs in stock
$70.78

Schneider Electric LC1E40BD Easy TeSys Contactor 3P 3NO AC-3 40 A ≤440V 24V DC Coil 1NO+1NC Contactor

Reference No: LC1E40BD
Catalog No: LC1E40BD
Rated Current (A): 40
Rated Voltage (VAC): 24 V DC
Number of Poles: 3P
0 pcs in stock
$86.27

Schneider Electric LC1E50BD Easy TeSys Contactor 3P 3NO AC-3 50 A ≤440V 24V DC Coil 1NO+1NC Contactor

Reference No: LC1E50BD
Catalog No: LC1E50BD
Rated Current (A): 50
Rated Voltage (VAC): 24 V DC
Number of Poles: 3P
0 pcs in stock
$106.25

Schneider Electric LC1E65BD Easy TeSys Contactor 3P 3NO AC-3 65 A ≤440V 24V DC Coil 1NO+1NC Contactor

Reference No: LC1E65BD
Catalog No: LC1E65BD
Rated Current (A): 65
Rated Voltage (VAC): 24 V DC
Number of Poles: 3P
0 pcs in stock
$136.71

Schneider Electric LC1E80BD Easy TeSys Contactor 3P 3NO AC-3 80 A ≤440V 24V DC Coil 1NO+1NC Contactor

Reference No: LC1E80BD
Catalog No: LC1E80BD
Rated Current (A): 80
Rated Voltage (VAC): 24 V DC
Number of Poles: 3P
0 pcs in stock
$158.37

Schneider Electric LC1E95BD Easy TeSys Contactor 3P 3NO AC-3 95 A ≤440V 24V DC Coil 1NO+1NC Contactor

Reference No: LC1E95BD
Catalog No: LC1E95BD
Rated Current (A): 95
Rated Voltage (VAC): 24 V DC
Number of Poles: 3P
0 pcs in stock
$215.21

Schneider Electric CA3KN40BD TeSys K Control Relay 4NO 24 V DC Coil Screw Clamp Auxiliary Contactor

Reference No: CA3KN40BD
Catalog No: CA3KN40BD
Rated Current (A): 10
Rated Voltage (VAC): 24 V DC
Number of Poles: 3P
0 pcs in stock
$24.36

Schneider Electric CA2KN22B7 TeSys K Control Relay 2NO 2NC 24 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CA2KN22B7
Catalog No: CA2KN22B7
Rated Current (A): 10
Rated Voltage (VAC): 24 V AC
Number of Poles: 3P
0 pcs in stock
$17.71

Schneider Electric CA3KN40ED TeSys K Control Relay 4NO 48 V DC Coil Screw Clamp Auxiliary Contactor

Reference No: CA3KN40ED
Catalog No: CA3KN40ED
Rated Current (A): 10
Rated Voltage (VAC): 48 V DC
Number of Poles: 3P
0 pcs in stock
$24.36

Schneider Electric CA2KN22E7 TeSys K Control Relay 2NO 2NC 48 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CA2KN22E7
Catalog No: CA2KN22E7
Rated Current (A): 10
Rated Voltage (VAC): 48 V AC
Number of Poles: 3P
0 pcs in stock
$17.71

Schneider Electric CA3KN40FD TeSys K Control Relay 4NO 110 V DC Coil Screw Clamp Auxiliary Contactor

Reference No: CA3KN40FD
Catalog No: CA3KN40FD
Rated Current (A): 10
Rated Voltage (VAC): 110 V DC
Number of Poles: 3P
0 pcs in stock
$24.36

Schneider Electric CA2KN22F7 TeSys K Control Relay 2NO 2NC 110 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CA2KN22F7
Catalog No: CA2KN22F7
Rated Current (A): 10
Rated Voltage (VAC): 110 V AC
Number of Poles: 3P
0 pcs in stock
$17.71

Schneider Electric CAD32B7 TeSys Deca Control Relay 3NO 2NC 24 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CAD32B7
Catalog No: CAD32B7
Rated Current (A): 10
Rated Voltage (VAC): 24 V AC
Number of Poles: 3P
0 pcs in stock
$25.12

Schneider Electric CA2KN22M7 TeSys K Control Relay 2NO 2NC 220-230 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CA2KN22M7
Catalog No: CA2KN22M7
Rated Current (A): 10
Rated Voltage (VAC): 220/230 V AC
Number of Poles: 3P
0 pcs in stock
$17.71

Schneider Electric CAD32D7 TeSys Deca Control Relay 3NO 2NC 42 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CAD32D7
Catalog No: CAD32D7
Rated Current (A): 10
Rated Voltage (VAC): 42 V AC
Number of Poles: 3P
0 pcs in stock
$25.12

Schneider Electric CA2KN22Q7 TeSys K Control Relay 2NO 2NC 380-400 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CA2KN22Q7
Catalog No: CA2KN22Q7
Rated Current (A): 10
Rated Voltage (VAC): 380/400 V AC
Number of Poles: 3P
0 pcs in stock
$17.71

Schneider Electric CAD32E7 TeSys Deca Control Relay 3NO 2NC 48 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CAD32E7
Catalog No: CAD32E7
Rated Current (A): 10
Rated Voltage (VAC): 48 V AC
Number of Poles: 3P
0 pcs in stock
$25.12

Schneider Electric CAD32ED TeSys Deca Control Relay 3NO 2NC 48 V DC Coil Screw Clamp Auxiliary Contactor

Reference No: CAD32ED
Catalog No: CAD32ED
Rated Current (A): 10
Rated Voltage (VAC): 48 V DC
Number of Poles: 3P
0 pcs in stock
$37.57

Schneider Electric CA2KN31B7 TeSys K Control Relay 3NO 1NC 24 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CA2KN31B7
Catalog No: CA2KN31B7
Rated Current (A): 10
Rated Voltage (VAC): 24 V AC
Number of Poles: 3P
0 pcs in stock
$17.71

Schneider Electric CA2KN31E7 TeSys K Control Relay 3NO 1NC 48 V AC Coil Screw Clamp Auxiliary Contactor

Reference No: CA2KN31E7
Catalog No: CA2KN31E7
Rated Current (A): 10
Rated Voltage (VAC): 48 V AC
Number of Poles: 3P
0 pcs in stock
$17.71

Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
  • Rated current and motor power at your operating voltage, with margin for the duty cycle.
  • Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
  • Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
  • Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.

FAQ

What is the difference between a contactor and a contactor relay?

A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.

Which standard applies to contactors?

Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.

Do you ship contactors outside Turkey?

Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.