Mersen 83010103 STMT1-50K150V-1P Surge Protection Device Type 1, 50kA Iimp (10/350), 1Ph, 120V, L-N, 1 Pole, Monobloc, 2 Modules
Mersen 83010102 STMT1-100K-N Surge Protection Device Type 1, 100kA Iimp (10/350), N, Neutral, 1 Pole, Monobloc, 2 Modules
Mersen 83010100 STMT1-50K275V-1P Surge Protection Device Type 1, 50kA Iimp (10/350), 1Ph, 230V, L-N, 1 Pole, Monobloc, 2 Modules
Siemens 5SD7481-0 5SD7 260V Surge Protective Device
Siemens 5SD7464-1 5SD7 350V Surge Protective Device
Siemens 5SD7464-0 5SD7 350V Surge Protective Device
Siemens 5SD7463-1 5SD7 350V Surge Protective Device
Siemens 5SD7463-0 5SD7 350V Surge Protective Device
Siemens 5SD7461-1 5SD7 350V Surge Protective Device
Siemens 5SD7461-0 5SD7 350V Surge Protective Device
Siemens 5SD7444-1 5SD7 350V Surge Protective Device
Siemens 5SD7443-1 5SD7 350V Surge Protective Device
Siemens 5SD7442-1 5SD7 350V Surge Protective Device
Siemens 5SD7414-1 5SD7 350V Surge Protective Device
Siemens 5SD7413-1 5SD7 350V Surge Protective Device
Siemens 5SD7412-1 5SD7 350V Surge Protective Device
Siemens 3WT8406-5UA75-5AB2 3WT8 4P 500V Air Circuit Breaker
Siemens 3WT8406-5UA71-0AA2 3WT8 4P 500V Air Circuit Breaker
Siemens 3WT8406-5AA05-5AB2 3WT8 4P 500V Air Circuit Breaker
Siemens 3WT8406-5AA01-0AA2 3WT8 4P 500V Air Circuit Breaker
Circuit breakers and protection devices from ABB, Siemens, Schneider Electric and Mersen cover the full low-voltage protection chain, from miniature circuit breakers to air circuit breakers up to 6300 A. The range includes MCB, MCCB, ACB, residual current devices, arc fault detection devices and surge protective devices in 1 to 4 poles, with more than 4,500 listed products. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Miniature Circuit Breakers (MCB) – DIN-rail overcurrent protection for final circuits and distribution boards.
- Molded Case Circuit Breakers (MCCB) – feeder and motor-circuit protection with adjustable trip units.
- Air Circuit Breakers (ACB) – main incomer and bus-tie breakers from 630 A to 6300 A.
- Residual Current Devices (RCD) – earth-leakage protection against shock and fire.
- Arc Fault Detection Devices (AFDD) – detection of series and parallel arcs in final circuits.
- Surge Protective Devices (SPD) – protection of installations against transient overvoltage.
How to choose
- Rated current and pole count, matched to the load and the neutral arrangement.
- Breaking capacity at the installation voltage, at or above the prospective short-circuit current.
- Standard: IEC 60898-1 for household and similar MCBs, IEC 60947-2 for industrial breakers, IEC 61008 and 61009 for RCDs.
- Trip characteristic or trip unit type, and coordination with upstream and downstream devices.
FAQ
What is the difference between an MCB and an MCCB?
An MCB is a DIN-rail breaker for final circuits, usually with fixed thermal-magnetic tripping. An MCCB covers higher currents and short-circuit levels and often has adjustable or electronic trip units.
Do I need an RCD in addition to a circuit breaker?
Yes, where earth-leakage protection is required. A standard breaker protects against overload and short circuit, while an RCD detects leakage current to earth.
Can you ship circuit breakers outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.