- Home
- VFD Accessories (Power Modules, Reactors, Panels)
- Siemens 6SL3210-1PH22-3UL0 SINAMICS G120 PM240-2 15kW/18.5kW 500-690V VFD Power Module Siemens 6SL3210-1PH22-3UL0 SINAMICS G120 PM240-2 15kW/18.5kW 500-690V VFD Power Module
Siemens 6SL3210-1PH22-3UL0 SINAMICS G120 PM240-2 15kW/18.5kW 500-690V VFD Power Module
Siemens 6SL3210-1PH22-3UL0 SINAMICS G120 PM240-2 15kW/18.5kW 500-690V VFD Power Module
Get Quote
- Description
The Siemens 6SL3210-1PH22-3UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 15.00 kW at high overload and 18.50 kW at low overload in the FSD frame. The module integrates a braking chopper, has no input filter, and ships without a control unit or operator panel; it runs from CU firmware V4.7 HF8. It weighs 17.4 kg with IP20 protection in the 472 x 200 x 237 mm FSD frame.
Technical Specifications
| Order Number (MLFB) | 6SL3210-1PH22-3UL0 |
| EAN | 4042948668283 |
| Brand | Siemens |
| Series | SINAMICS G120 |
| Frame Size | FSD |
| Dimensions (H x W x D) | 472 x 200 x 237 mm |
| Country of Origin | DE |
| Number of phases | 3 AC |
| Line voltage | 500 ... 690 V ±10 % |
| Line frequency | 47 ... 63 Hz |
| Rated input current (LO) | 22.00 A |
| Rated input current (HO) | 20.00 A |
| Rated voltage | 690V IEC / 600V NEC |
| Rated power (LO) | 18.50 kW / 20.00 hp |
| Rated power (HO) | 15.00 kW / 15.00 hp |
| Rated output current (LO) | 23.00 A |
| Rated output current (HO) | 19.00 A |
| Max. output current | 38.00 A |
| Pulse frequency | 2 kHz |
| Output frequency for vector control | 0 ... 200 Hz |
| Output frequency for V/f control | 0 ... 550 Hz |
| Power loss | 0.48 kW |
| Cooling | Internal air cooling |
| Cooling air requirement | 0.055 m³/s (1.942 ft³/s) |
| Installation altitude | 1,000 m (3,280.84 ft) |
| Operation LO | -20 ... 40 °C (-4 ... 104 °F) |
| Operation HO | -20 ... 50 °C (-4 ... 122 °F) |
| Transport | -25 ... 55 °C (-13 ... 131 °F) |
| Storage | -25 ... 55 °C (-13 ... 131 °F) |
| Net weight | 17.4 kg |
Selection Notes
This is the top of the mid-range FSD lineup in this batch before stepping up to the FSE frame at 37.00 kW low-overload; pick it over the 11.00 kW / 15.00 kW module when the driven load's continuous current draw is closer to 23.00 A than to 19.00 A. Max. output current of 38.00 A gives headroom for the 200% / 3 s overload window on high-overload duty, which matters for machines with high breakaway torque, such as positive-displacement pumps. Since the module ships unfiltered, plan for an external EMC filter if conducted-emission limits apply to the installation.