Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- Siemens SENTRON 3VM MCCBs
Filter
Siemens SENTRON 3VM MCCBs
Siemens 3VM1116-3ED32-0AA0 3VM1 3P 160A 25kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1112-4EE42-0AA0 3VM1 4P 125A 36kA 415V TM220 LI Molded Case Circuit Breaker
Siemens 3VM1116-3EE32-0AA0 3VM1 3P 160A 25kA 415V TM220 LI Molded Case Circuit Breaker
Siemens 3VM1112-5MH32-0AA0 3VM1 3P 125A 55kA 415V TM120M I Molded Case Circuit Breaker
Siemens 3VM1112-4ED32-0AA0 3VM1 3P 125A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1116-4ED42-0AA0 3VM1 4P 160A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1120-5MH32-0AA0 3VM1 3P 20A 55kA 415V TM120M I Molded Case Circuit Breaker
Siemens 3VM1112-4ED42-0AA0 3VM1 4P 125A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1116-4EE42-0AA0 3VM1 4P 160A 36kA 415V TM220 LI Molded Case Circuit Breaker
Siemens 3VM1096-4ED42-0AA0 3VM1 4P 16A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1116-4ED32-0AA0 3VM1 3P 160A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1080-4ED32-0AA0 3VM1 3P 80A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1096-4ED32-0AA0 3VM1 3P 16A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1096-3ED32-0AA0 3VM1 3P 16A 25kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1096-3ED42-0AA0 3VM1 4P 16A 25kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1050-4ED32-0AA0 3VM1 3P 50A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1110-5MH32-0AA0 3VM1 3P 100A 55kA 415V TM120M I Molded Case Circuit Breaker
Siemens 3VM1063-4ED42-0AA0 3VM1 4P 63A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1040-3ED42-0AA0 3VM1 4P 40A 25kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1050-3ED42-0AA0 3VM1 4P 50A 25kA 415V TM210 LI Molded Case Circuit Breaker
Siemens SENTRON 3VM MCCBs are molded case circuit breakers for 16 A to 630 A distribution circuits. The range covers 3-pole and 4-pole breakers at 415 V, with more than 100 products. Stoklink ships worldwide from Turkey and quotes volumes on request.
What's in this range
- 3VM1 breakers in several frame sizes.
- TM210, TM220 and similar thermal-magnetic trip units.
- Breaking capacities of 25 kA and 36 kA at 415 V in the listed parts.
- Higher ratings: Siemens SENTRON 3VA MCCBs.
How to choose
- Frame size and rated current must cover the load.
- Breaking capacity at 415 V must exceed the fault level.
- Pole count follows the neutral arrangement.
FAQ
What does LI mean in a 3VM title?
LI refers to the protection functions of the trip unit, long-time and instantaneous.
When should I pick 3VA over 3VM?
For ratings above 630 A or where electronic trip units are required, choose 3VA.
Do you export 3VM breakers?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.