The Schneider Electric LC1G2654LSEA is a 4-pole TeSys Giga high-power contactor rated 385 A AC-1 at up to 440 V, built for heavy power-switching duty rather than motor AC-3 starting. It runs on a 200-500 V AC/DC wide-band electronic coil with built-in peak limiting, ships with a 1 NO + 1 NC auxiliary contact block and local Contact Wear Diagnosis, and mounts on a plate 185 mm wide.
Technical Specifications
| Reference | LC1G2654LSEA |
| Brand | Schneider Electric |
| Range | TeSys Giga |
| GTIN | 3606481922762 |
| Device Short Name | LC1G |
| Product Type | Contactor |
| Poles | 4P, 4 NO |
| Utilisation Category | AC-1 (power switching) |
| Rated Operational Voltage (Ue) | ≤1000 V AC 50/60 Hz / ≤460 V DC |
| Rated Operational Current, AC-1 (Ith) | 385 A at ≤1000 V |
| Rated Operational Current, AC-3 (Ie) | 265 A at ≤440 V |
| Control Circuit Voltage (Uc) | 200-500 V AC/DC |
| Rated Breaking Capacity | 2380 A at 440 V |
| Rated Making Capacity (Irms) | 3320 A at 440 V |
| Rated Short-Time Withstand Current (Icw) | 2.2 kA (10 s) / 0.95 kA (1 min) / 0.48 kA (10 min) |
| Associated Fuse Rating | 315 A aM (≤440 V) / 400 A gG (≤690 V) / 450 A UL Type J (≤600 V) |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Power Dissipation per Pole | 20 W AC-1 / 11 W AC-3 |
| Inrush Power | 530 VA AC / 300 W DC |
| Maximum Operating Rate | 600 cyc/h AC-3 / 300 cyc/h AC-1 |
| Mounting | Plate |
| IP Degree of Protection | IP2X front face with shrouds |
| Dimensions (H x W x D) | 290 mm x 185 mm x 226 mm |
| Net Weight | 8.9 kg |
Certifications & Standards
- CB Scheme
- CCC
- cULus
- EAC
- CE
- UKCA
- EU-RO-MR by DNV-GL
- EN/IEC 60947-4-1
- EN/IEC 60947-5-1
- UL 60947-4-1
- CSA C22.2 No 60947-4-1
- JIS C8201-4-1
- JIS C8201-5-1
- UL 60335-1
- UL 60335-2-40
Selection Notes
The 4P/4NO contact arrangement with AC-1-only duty targets heavy resistive or power-distribution switching rather than three-phase motor starting; for motor AC-3 duty at a comparable frame size, pick the corresponding 3-pole Giga variant instead. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. The 200-500 V AC/DC coil spans the whole band without a separate coil code per voltage, which simplifies sourcing across regions.