- Home
- Schneider Altivar Drives
- Schneider Electric ATV630U30N4 Altivar Process ATV630 3 kW 380-480 V 3-Phase IP21 Variable Frequency Drive Schneider Electric ATV630U30N4 Altivar Process ATV630 3 kW 380-480 V 3-Phase IP21 Variable Frequency Drive
Schneider Electric ATV630U30N4 Altivar Process ATV630 3 kW 380-480 V 3-Phase IP21 Variable Frequency Drive
Schneider Electric ATV630U30N4 Altivar Process ATV630 3 kW 380-480 V 3-Phase IP21 Variable Frequency Drive
Get Quote
- Description
The Schneider Electric ATV630U30N4 is a 3-phase Altivar Process ATV630 variable frequency drive rated for 3 kW motors at 380-480 V AC, with a continuous output current of 7.2 A. It integrates Safe Torque Off (STO) SIL 3 safety, native Ethernet, Modbus TCP and Modbus serial ports, and ships in an IP21 / UL Type 1 enclosure for wall mounting. Normal duty allows overload to 120% of In; heavy duty extends to 150% for harder-starting loads.
Technical Specifications
| Reference | ATV630U30N4 |
| Brand | Schneider Electric |
| Range | Altivar Process ATV600 |
| GTIN | 3606480758126 |
| Product Type | Variable speed drive |
| Phase | 3-phase |
| Rated Supply Voltage (Us) | 380-480 V AC (-15% / +10%) |
| Supply Frequency | 50-60 Hz (±5%) |
| Motor Power, Normal Duty | 3 kW |
| Motor Power, Heavy Duty | 2.2 kW |
| Nominal Output Current | 7.2 A |
| Line Current | 5.8 A at 380 V / 5.1 A at 480 V (normal duty) |
| Overload Capability | 120% for 60 s (normal duty) / 150% for 60 s (heavy duty) |
| IP Degree of Protection | IP21 / UL Type 1 (UL 508C) |
| Mounting Mode | Wall mount |
| Switching Frequency | 2-12 kHz adjustable (4 kHz nominal) |
| EMC Filter | Integrated, 50 m C2 / 150 m C3 (IEC 61800-3) |
| Safety Function | STO (Safe Torque Off), SIL 3 |
| Discrete I/O | 8 discrete inputs, 3 analog inputs, 2 analog outputs |
| Relay Outputs | 3 (R1 fault NO/NC, R2/R3 sequence NO), 3 A 250 V AC resistive |
| Communication Port | Ethernet, Modbus TCP, Modbus serial (RS 485) |
| Power Dissipation | 31 W natural convection / 78 W forced convection at 380 V |
| Noise Level | 54.5 dB |
| Dimensions (W x D x H) | 144 x 203 x 350 mm |
| Net Weight | 4.6 kg |
Certifications & Standards
- CE
- UL
- CSA
- IEC 61800-5-1
Selection Notes
The ATV630U30N4 covers motors up to 3 kW at 400 V in normal duty (120% overload for 60 s); where starts are longer or more frequent, size to the 2.2 kW heavy-duty rating (150% overload for 60 s) instead of the higher normal-duty figure. Its 7.2 A continuous output is the number to match against the motor's nameplate current, not the kW label, since actual full-load current varies with motor efficiency. The integrated STO input removes torque directly at the drive without an external contactor, which simplifies wiring a safety circuit around the motor. Native Ethernet and Modbus TCP let a PLC or SCADA system read drive status and write speed references without a separate gateway; step up to a higher-power ATV630 model if the application's motor exceeds this frame's rating.
Applications
The ATV630 targets fluid-handling and process loads: pumps, fans and compressors in water and wastewater treatment, oil and gas, mining and minerals, and food and beverage processing. The Stop-and-Go standby function cuts energy use on intermittent pump and fan duty without extra hardware.