- Home
- Schneider Altivar Drives
- Schneider Electric ATH230U11N4 Altivar HVAC ATH230 1.1 kW 380-500 V 3-Phase IP20 Variable Frequency Drive Schneider Electric ATH230U11N4 Altivar HVAC ATH230 1.1 kW 380-500 V 3-Phase IP20 Variable Frequency Drive
Schneider Electric ATH230U11N4 Altivar HVAC ATH230 1.1 kW 380-500 V 3-Phase IP20 Variable Frequency Drive
Schneider Electric ATH230U11N4 Altivar HVAC ATH230 1.1 kW 380-500 V 3-Phase IP20 Variable Frequency Drive
Get Quote
- Description
The Schneider Electric ATH230U11N4 is a 3-phase Altivar HVAC ATH230 variable speed drive for HVAC OEM panels, rated for 1.1 kW motors at 380-500 V. It mounts in IP20 enclosures, integrates Safe Torque Off (STO) safety rated SIL 3 / PL e, and communicates over Modbus serial and BACnet MS/TP for direct building management system integration.
Technical Specifications
| Reference | ATH230U11N4 |
| Brand | Schneider Electric |
| Range | Altivar HVAC ATH200 |
| Device Short Name | ATH230 |
| GTIN | 3606487882121 |
| Product Type | Variable speed drive |
| Phase | 3-phase |
| Rated Supply Voltage | 380-500 V (-15% / +10%) |
| Supply Frequency | 50-60 Hz (±5%) |
| Nominal Output Current | 3.0 A |
| Motor Power | 1.1 kW |
| Apparent Power | 3.3 kVA at 500 V |
| Power Dissipation | 40 W |
| Switching Frequency | 2-16 kHz adjustable (4 kHz nominal) |
| IP Degree of Protection | IP20 |
| Mounting Mode | Cabinet mount |
| Safety Function | STO (Safe Torque Off) |
| Safety Level | SIL 3 (IEC 61508), PL e (ISO 13849-1) |
| EMC Filter | Class C2 EMC filter integrated |
| Communication Port Protocol | Modbus serial, BACnet MS/TP (BACnet/IP via optional module) |
| Prospective Line Isc | 5 kA |
| Dimensions (W x D x H) | 105 x 158 x 142 mm |
| Net Weight | 1.3 kg |
| Volume of Cooling Air | 18 m³/h |
| Noise Level | 51 dB |
Certifications & Standards
- cULus
- CE
- UKCA
- KC
- EAC
- ATEX
- RCM
- IEC 61800-5-1
- IEC 61800-3
- UL 508C
- IEC 60721-3
- IEC 61508
- IEC 13849-1
Selection Notes
Size the ATH230U11N4 to the driven motor's nameplate current, not the drive's frame rating: its 3.0 A nominal output current at 380-500 V sets the ceiling for the connected pump, fan, or compressor motor. Within the ATH230 line, the 380-500 V 3-phase variant applies where the panel's incoming supply is 3-phase at that voltage band — pick the opposite phase/voltage sibling if the OEM panel's incoming feed differs. The integrated STO input lets the drive sit inside a safety circuit (SIL 3 / PL e) without an external contactor to remove torque, and the native Modbus and BACnet MS/TP ports let a building automation system read status and write speed setpoints directly, without a protocol gateway.