- Description
The Schneider Electric ATH230U04M2 is a single-phase Altivar HVAC ATH230 variable speed drive for compact HVAC OEM panels, rated for 0.37 kW motors at 200-240 V. It mounts in IP20 enclosures, integrates Safe Torque Off (STO) safety rated SIL 3 / PL e, and communicates over Modbus serial and BACnet MS/TP for direct building management system integration.
Technical Specifications
| Reference | ATH230U04M2 |
| Brand | Schneider Electric |
| Range | Altivar HVAC ATH200 |
| Device Short Name | ATH230 |
| GTIN | 3606487957614 |
| Product Type | Variable speed drive |
| Phase | 1-phase |
| Rated Supply Voltage | 200-240 V (-15% / +10%) |
| Supply Frequency | 50-60 Hz (±5%) |
| Nominal Output Current | 3.3 A |
| Motor Power | 0.37 kW |
| Apparent Power | 1.2 kVA at 240 V |
| Power Dissipation | 30 W |
| Switching Frequency | 2-16 kHz adjustable (4 kHz nominal) |
| IP Degree of Protection | IP20 |
| Mounting Mode | Cabinet mount |
| Safety Function | STO (Safe Torque Off) |
| Safety Level | SIL 3 (IEC 61508), PL e (ISO 13849-1) |
| EMC Filter | Class C2 EMC filter integrated |
| Communication Port Protocol | Modbus serial, BACnet MS/TP (BACnet/IP via optional module) |
| Prospective Line Isc | 1 kA |
| Dimensions (W x D x H) | 72 x 128 x 143 mm |
| Net Weight | 1.0 kg |
Certifications & Standards
- cULus
- CE
- UKCA
- KC
- EAC
- ATEX
- RCM
- IEC 61800-5-1
- IEC 61800-3
- UL 508C
- IEC 60721-3
- IEC 61508
- IEC 13849-1
Selection Notes
Size the ATH230U04M2 to the driven motor's nameplate current, not the drive's frame rating: its 3.3 A nominal output current at 200-240 V sets the ceiling for the connected pump, fan, or compressor motor. Within the ATH230 line, the 200-240 V single-phase variant applies where the panel's incoming supply is 1-phase at that voltage band — pick the opposite phase/voltage sibling if the OEM panel's incoming feed differs. The integrated STO input lets the drive sit inside a safety circuit (SIL 3 / PL e) without an external contactor to remove torque, and the native Modbus and BACnet MS/TP ports let a building automation system read status and write speed setpoints directly, without a protocol gateway.