Schneider Electric ATS490C17Y Altivar ATS490 170A 208-690V AC 90 kW Soft Starter
Schneider Electric ATS490C17Y Altivar ATS490 170A 208-690V AC 90 kW Soft Starter
Get Quote
- Description
The Schneider Electric ATS490C17Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 170 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 90 kW at 400 V (75 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP/EtherNet/IP port support supervised, cybersecure motor control from the same enclosure.
Technical Specifications
| Reference | ATS490C17Y |
| GTIN | 3606486948859 |
| Brand | Schneider Electric |
| Range of Product | Altivar Soft Starter ATS490 |
| Product Type | Soft starter |
| Phase | 3 phase |
| Supply Voltage (Ue) | 208...690 V AC (-15...+10%) |
| Supply Frequency | 50...60 Hz |
| Rated Operational Current – Normal Duty (Ie) | 170 A at 40 °C |
| Rated Operational Current – Heavy Duty | 140 A at 40 °C |
| Motor Power at 400 V – Normal Duty | 90 kW |
| Motor Power at 400 V – Heavy Duty | 75 kW |
| Control Circuit Voltage (Us) | 110...230 V AC, 50/60 Hz |
| Control Circuit Voltage (Uc) | 24 V DC |
| Apparent Power | 80 VA |
| IP Degree of Protection | IP00 |
| Safe Torque Off (STO) | SIL 1 (IEC 61508), PL c / Category 2 (ISO 13849) |
| Communication | Modbus serial, Modbus TCP/EtherNet/IP |
| Discrete Inputs / Relay Outputs | 5 digital inputs, 3 relay outputs, 2 digital outputs |
| Rated Insulation Voltage (Ui) | 690 V |
| Dimensions (W x D x H) | 160 x 235 x 356 mm |
| Net Weight | 10 kg |
Certifications & Standards
- CE
- cULus
- UKCA
- CCC
- EN/IEC 60947-4-2
Selection Notes
At 170 A normal duty, the ATS490C17Y covers motors up to 90 kW at 400 V; size on the heavy-duty rating (140 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie / 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 90 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.