- Home
- Schneider Altistart Soft Starters
- Schneider Electric ATS480C48Y Altivar ATS480 480 A 208-690 V 250 kW Soft Starter Schneider Electric ATS480C48Y Altivar ATS480 480 A 208-690 V 250 kW Soft Starter
Schneider Electric ATS480C48Y Altivar ATS480 480 A 208-690 V 250 kW Soft Starter
Schneider Electric ATS480C48Y Altivar ATS480 480 A 208-690 V 250 kW Soft Starter
Get Quote
- Description
The Schneider Electric ATS480C48Y is an Altivar ATS480 soft starter rated for 480 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 410 A, and at 400 V it starts motors up to 250 kW in normal duty (220 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.
Technical Specifications
| Reference | ATS480C48Y |
| GTIN | 3606481089144 |
| Brand | Schneider Electric |
| Range | Altivar Soft Starter ATS480 |
| Rated Operational Current (Ie) – Normal Duty | 480 A at 40°C |
| Rated Operational Current – Heavy Duty | 410 A at 40°C |
| Supply Voltage (Ue) | 208-690 V AC |
| Supply Frequency | 50-60 Hz |
| Control Circuit Voltage (Us) | 110-230 V AC |
| Control Circuit Voltage (Uc) | 24 V DC |
| Motor Power at 400 V – Normal Duty | 250 kW |
| Motor Power at 400 V – Heavy Duty | 220 kW |
| Current Limiting (5 x Ie max) | 150-700% In |
| IP Degree of Protection | IP00 |
| Communication Port | Modbus serial, 1 RJ45 |
| Discrete Inputs / Relay Outputs | 4 / 3 |
| Rated Insulation Voltage (Ui) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Dimensions (W x D x H) | 400 x 314 x 670 mm |
| Net Weight | 51.4 kg |
Certifications & Standards
- CE
- cULus
- CCC
- UKCA
- RCM
- EAC
- DNV
- ABS
- BV
- CCS
- IEC 60947-4-2
- UL 60947-4-2
- IEC 60664-1
Selection Notes
The ATS480C48Y is sized for the 250 kW normal-duty / 220 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 410 A, or the next size up if it exceeds 480 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.
Applications
The ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.