- Schneider Electric ATS430C17S6 Altivar ATS430 170A 208-600V 90kW Soft Starter Schneider Electric ATS430C17S6 Altivar ATS430 170A 208-600V 90kW Soft Starter
Schneider Electric ATS430C17S6 Altivar ATS430 170A 208-600V 90kW Soft Starter
Schneider Electric ATS430C17S6 Altivar ATS430 170A 208-600V 90kW Soft Starter
Get Quote
- Description
The Schneider Electric ATS430C17S6 is a 3-phase Altivar Soft Starter ATS430 rated for 170A continuous operation on a 208-600V AC supply. It drives asynchronous motors up to 110kW depending on line voltage, using torque control and an internal bypass to limit heat dissipation once the motor is running at speed, with 4 digital inputs and 2 relay outputs for control wiring.
Technical Specifications
| Reference | ATS430C17S6 |
| Brand | Schneider Electric |
| Range | Altivar Soft Starter ATS430 |
| GTIN | 3606486948682 |
| Product Type | Soft starter |
| Phase | 3 phase |
| Rated operational current (Ie) | 170 A at 40 °C, normal duty |
| Supply voltage (Ue) | 208...600 V AC (-15...+10%) |
| Control circuit voltage (Us) | 110...230 V AC 50-60 Hz (-15...+10%) |
| Motor power | 45 kW at 230 V | 90 kW at 400 V | 90 kW at 440 V | 110 kW at 500 V | 110 kW at 525 V |
| IP Degree of Protection | IP00 |
| Torque control | Yes |
| Overload current | 400% Ie for 13 s |
| Discrete inputs | 4 (STOP, RUN, DI3, DI4) |
| Relay outputs | 2 (2 A / 250 V AC or 2 A / 30 V DC) |
| Analogue I/O | 1 input (PTC probe), 1 output (0-20/4-20 mA or 0-10 V) |
| Communication | Modbus serial (RJ45 or open-style terminals) |
| Rated insulation voltage (Ui) | 600 V |
| Rated impulse withstand voltage (Uimp) | 6 kV |
| Internal bypass | Yes |
| Operating position | Vertical ± 10° |
| Dimensions (H x W x D) | 356 x 160 x 231.5 mm |
| Net weight | 8.60 kg |
Certifications & Standards
- cULus
- CE
- UKCA
- CCC
- RCM
- EAC
- KC
- EN/IEC 60947-4-2
- UL 60947-4-2
- IEC 60664-1
Selection Notes
The 170A rating sizes the ATS430C17S6 for motors from 45kW at 230V up to 110kW at 500-525V, so match the drive to the actual line voltage rather than the current figure alone. The 400% Ie for 13s overload rating and internal bypass keep dissipation low once the motor reaches full speed, which matters most on loads with frequent start/stop cycling. Pick the next size up in the ATS430 range when the driven load's starting torque or duty cycle exceeds the 170A frame's 13-second overload window; pick the size below it when the motor's full-load current sits well under 170A, since an oversized starter loses current-limiting resolution.