The Siemens 6EP1961-2BA61 is a SITOP PSE200U selectivity module that splits a 24 V DC/12 A input into four individually protected 3 A NEC Class 2 outputs, with a status signal output per channel instead of one shared alarm contact. Each output trips independently at an adjustable 0.5-3 A threshold set via potentiometer, and its pulse/pause status signal can be evaluated directly by a Simatic function block.
Technical Specifications
| Order Number | 6EP1961-2BA61 |
| Brand | Siemens |
| Series | SITOP PSE200U |
| Product Designation | PSE200U Selectivity Module |
| Input Voltage | 24 V DC (22 ... 30 V) |
| Input Current (rated) | 12 A |
| Number of Outputs | 4 |
| Output Current per Output (rated) | 3 A |
| Adjustable Current Threshold | 0.5 ... 3 A via potentiometer |
| Response Delay (max) | 5 s |
| Signaling | Status signal output per channel, pulse/pause, Simatic function block evaluable |
| Efficiency | 97% |
| Power Loss (typical) | 9 W |
| Protection Class IP | IP20 |
| Operating Resource Protection Class | Class III |
| Ambient Temperature (Operation) | -25 ... +60 degC |
| Enclosure Dimensions (W x H x D) | 72 x 80 x 72 mm |
| Mounting | DIN rail EN 60715 35x7.5/15 |
| Net Weight | 0.2 kg |
| MTBF at 40 degC | 755,915 h |
| Country of Origin | RO |
Certifications & Standards
- CE
- UKCA
- EAC
- CB
- Shipbuilding
- ABS
- DNV
- EPD
Selection Notes
Pick the 2BA61 over the 2BA51 when the controller needs to identify which of the four channels tripped, not just that one has - the per-output pulse/pause signal line resolves fault location without extra wiring back to a shared contact. The signal is built for direct evaluation by a Simatic function block, which fits a SIMATIC-based control architecture more directly than a shared relay contact. Everything else - the 12 A input rating, 0.5-3 A adjustable trip point, IP20 enclosure - is identical across the PSE200U line, so the choice comes down to how much per-channel diagnostic resolution the application needs.