- Home
- Power Quality, Metering & Power Supplies
- Siemens 6EP1333-2BA20 SITOP PSU100S 24V/5A 120/230V AC Power Supply Siemens 6EP1333-2BA20 SITOP PSU100S 24V/5A 120/230V AC Power Supply
Siemens 6EP1333-2BA20 SITOP PSU100S 24V/5A 120/230V AC Power Supply
Siemens 6EP1333-2BA20 SITOP PSU100S 24V/5A 120/230V AC Power Supply
Get Quote
- Description
The Siemens 6EP1333-2BA20 is a SITOP PSU100S DIN-rail power supply that converts 120/230 V AC input into a stabilized 24 V DC output rated at 5 A. It operates with automatic input voltage range selection, delivers 88% efficiency, and provides a 20 ms buffer time on the output during a mains interruption. The output voltage is adjustable from 22.8 to 28 V via potentiometer.
Technical Specifications
| SKU | 6EP1333-2BA20 |
| Brand | Siemens |
| Series | SITOP PSU100S |
| Input Voltage | 120 V / 230 V AC, automatic range selection |
| Input Voltage Range 1 | 85 ... 132 V AC |
| Input Voltage Range 2 | 170 ... 264 V AC |
| Line Frequency | 47 ... 63 Hz |
| Output Voltage | 24 V DC, adjustable 22.8 ... 28 V |
| Output Current | 5 A rated, 0 ... 6 A range |
| Efficiency | 88% |
| Buffering Time | 20 ms minimum at rated output current |
| Short-Circuit Response | Constant current characteristic, 6 ... 7.1 A |
| Protection Class | IP20 |
| Ambient Temperature | -25 ... +70 °C during operation |
| Mounting | DIN rail EN 60715 35x7.5/15 |
| Dimensions (W x H x D) | 50 x 125 x 120 mm |
| Net Weight | 0.5 kg |
Certifications & Standards
- CE marking
- UKCA marking
- EAC approval
- CB-certificate
- Shipbuilding approval
- French marine classification society (BV)
- Det Norske Veritas (DNV)
- Environmental Product Declaration
Selection Notes
The 5 A rating covers a control cabinet with a compact CPU, an HMI panel, and a modest set of 24 V field devices without stacking additional supplies. Loads that regularly exceed the 6 A overload ceiling need the higher-current PSU100S variant in the same enclosure family instead. The 800 ms overload window at up to 18 A absorbs the inrush from contactor coils or lamp loads without nuisance-tripping the upstream miniature circuit breaker, and two units can run in parallel to double the available output current on the same DIN rail.
Applications
Fits control panels, ET 200 remote I/O stations, and PLC/HMI power distribution in cabinets already standardized on SITOP. The -25°C to +70°C operating range with natural convection covers unheated enclosures and outdoor cabinets within the 47-63 Hz mains tolerance.