- Home
- Power Quality, Metering & Power Supplies
- Schneider Electric METSEPM5650 PowerLogic PM5650 Waveform Capture Class 0.2S 63rd Harmonic Power Meter Schneider Electric METSEPM5650 PowerLogic PM5650 Waveform Capture Class 0.2S 63rd Harmonic Power Meter
Schneider Electric METSEPM5650 PowerLogic PM5650 Waveform Capture Class 0.2S 63rd Harmonic Power Meter
Schneider Electric METSEPM5650 PowerLogic PM5650 Waveform Capture Class 0.2S 63rd Harmonic Power Meter
Get Quote
- Description
The Schneider Electric METSEPM5650 is a PowerLogic PM5650 flush-mount power meter that adds waveform capture with voltage sag and swell detection to the PM5560 base platform. It delivers Class 0.2S accuracy to IEC 62053-22 at 128 samples per cycle, measures voltage, current, power, energy and harmonics to the 63rd order, and monitors neutral current directly with calculated ground current.
Technical Specifications
| Reference | METSEPM5650 |
| GTIN | 3606489869717 |
| Brand | Schneider Electric |
| Range | PowerLogic PM5000 |
| Device Short Name | PM5650 |
| Accuracy Class | Class 0.2S active energy (IEC 62053-22) |
| Power Quality Analysis | Up to the 63rd harmonic, waveform capture, voltage sag/swell detection |
| Sampling Rate | 128 samples/cycle |
| Rated Supply Voltage (Us) | 90-528 V AC 45-65 Hz / 100-300 V DC |
| Rated Current Input (In) | 1 A or 5 A |
| Network Type | 1P+N, 3P, 3P+N |
| Measurement Voltage | 20-400 V AC phase-neutral / 20-828 V AC phase-phase |
| Metering Type | Measured neutral current, calculated ground current |
| Digital Inputs | 4, WAGES-capable |
| Digital Outputs | 2 |
| Alarms | 52 configurable |
| Communication | RS485 Modbus RTU/ASCII; 2 x Ethernet RJ45, Modbus TCP/IP, BACnet/IP, DNP3 |
| Memory Capacity | 1.1 MB |
| Display | Monochrome graphic LCD, 128 x 128 px |
| Mounting | Flush-mounted, 96 x 96 mm |
| IP Rating | IP30 rear / IP54 display |
| Dimensions (W x D x H) | 96 x 72 x 96 mm |
| Weight | 0.45 kg |
Certifications & Standards
- CE
- cULus
- EN 50470-1
- EN 50470-3
- IEC 61557-12
- IEC 62053-22
- ANSI C12.20
Selection Notes
The PM5650 adds waveform capture with sag/swell detection to the PM5560 base, so it is the right choice when nuisance trips or sensitive-equipment faults need to be correlated against the actual voltage disturbance waveform rather than just a logged event timestamp. Everything else - Class 0.2S accuracy, 63rd-harmonic analysis, dual Ethernet, 52 alarms - matches the PM5560. Choose the PM5760 instead if residual-current monitoring is also needed on top of waveform capture.