- Home
- I/O Modules & Remote I/O
- Siemens 6ES7226-6RA32-0XB0 SIMATIC S7-1200 SM 1226 F-DQ 2x Relay 5A PL e SIL3 Fail-safe PLC I/O Module Siemens 6ES7226-6RA32-0XB0 SIMATIC S7-1200 SM 1226 F-DQ 2x Relay 5A PL e SIL3 Fail-safe PLC I/O Module
Siemens 6ES7226-6RA32-0XB0 SIMATIC S7-1200 SM 1226 F-DQ 2x Relay 5A PL e SIL3 Fail-safe PLC I/O Module
Siemens 6ES7226-6RA32-0XB0 SIMATIC S7-1200 SM 1226 F-DQ 2x Relay 5A PL e SIL3 Fail-safe PLC I/O Module
Get Quote
- Description
The Siemens 6ES7226-6RA32-0XB0 is a SIMATIC S7-1200 fail-safe digital output module, SM 1226 F-DQ 2x relay/5A, rated up to Performance Level e per ISO 13849-1 and SIL 3 per IEC 61508. It supplies two safety relay circuits switching 5 V-30 V DC or 5 V-250 V AC loads, up to 5 A per circuit and 10 A total, and communicates safety data over PROFIsafe.
Technical Specifications
| Order Number | 6ES7226-6RA32-0XB0 |
| Brand | Siemens |
| Series | SIMATIC S7-1200 |
| Product Type Designation | SM 1226, F-DQ 2x relay/5 A |
| Supply Voltage (DC) | 20.4-28.8 V |
| Digital Outputs | 2 (Relay) |
| Output Voltage (DC) | 5-30 V DC |
| Output Voltage (AC) | 5-250 V AC |
| Output Current, max. | 5 A per circuit, 10 A total |
| Performance Level (ISO 13849-1) | Category 4, PL e |
| SIL (IEC 61508) | SIL 3 |
| PFDavg (SIL3) | < 1.00E-05 |
| PFH (SIL3) | < 4.00E-09 |
| Degree of Protection | IP20 |
| Width | 70 mm |
| Height | 100 mm |
| Depth | 75 mm |
| Weight | approx. 300 g |
| Country of Origin | CN |
Certifications & Standards
- CE
- cULus
- FM
Selection Notes
The F-DQ prefix marks this as a fail-safe output module for PROFIsafe segments, distinct from a standard SM 1226 relay module — choose it when the application's risk assessment calls for Category 4, PL e or SIL 3 output switching, such as an E-stop chain or guard interlock. Two independent relay circuits, each rated 5 A, cover contactor coils or small motor starters directly without an external safety relay; the 10 A total-circuit limit is the ceiling to check against the combined connected load.
Applications
Used with an S7-1200 F-CPU on machine safety circuits such as emergency-stop chains, safety guard interlocks, and contactor coil switching where PROFIsafe output diagnostics and SIL 3 / PL e rated switching are required.