Siemens 6ES7214-1HG40-0XB0 SIMATIC S7-1200 CPU 1214C DC/DC/Relay 14DI/10DO/2AI Programmable Logic Controller
Siemens 6ES7214-1HG40-0XB0 SIMATIC S7-1200 CPU 1214C DC/DC/Relay 14DI/10DO/2AI Programmable Logic Controller
Get Quote
- Description
Siemens 6ES7214-1HG40-0XB0 is a SIMATIC S7-1200 CPU 1214C, DC/DC/relay version, with 14 integrated 24 V DC digital inputs, 10 relay outputs rated 2 A each, and 2 analog voltage inputs on board. It has 150 KB of work memory, an integrated PROFINET interface supporting up to 16 connected IO devices, and runs from a 20.4-28.8 V DC supply drawing 500 mA typical.
Technical Specifications
| SKU | 6ES7214-1HG40-0XB0 |
| Brand | Siemens |
| Series | SIMATIC S7-1200 |
| Product Designation | CPU 1214C DC/DC/relay |
| Digital Inputs | 14 (24 V DC, sourcing/sinking) |
| Digital Outputs | 10 relay (2 A resistive max., 30 W DC / 200 W AC lamp load) |
| Analog Inputs | 2 (0-10 V, 10-bit) |
| Work Memory | 150 KB integrated |
| Load Memory | 4 MB integrated |
| Supply Voltage | 24 V DC (20.4-28.8 V) |
| Current Consumption | 500 mA (CPU only) / 1,500 mA max. with expansions |
| Communication | PROFINET (1x RJ45, 100 Mbit/s), PROFIBUS/AS-Interface via CM, OPC UA Server |
| Max. Expansion Modules | 8 signal modules, 3 communication modules, 1 signal board |
| High-Speed Counters | 6 (up to 100 kHz single-phase / 80 kHz differential) |
| Real-Time Clock | Yes, 480 h typ. backup, +/-60 s/month deviation |
| Weight | 0.384 kg |
Certifications & Standards
- CE
- UL
- cULus
- FM
- RCM
- KC
- Marine
Selection Notes
The 1214C sits above the 1212C in the S7-1200 line on I/O count (14DI/10DO/2AI) and offers 150 KB work memory, more than the smaller CPUs in the line - pick it when the application needs the extra local I/O without adding a signal module. The relay-output (DC/DC/relay) variant switches AC or DC loads directly up to 2 A per point, unlike a DC/DC/DC variant's transistor outputs, which is useful for driving contactors or pilot lights without an interposing relay. A single onboard PROFINET port with up to 16 connected IO devices covers most single-cell machines; multi-cell lines needing PROFIBUS or AS-Interface require an added communication module.
Applications
Used as the main controller on standalone machines and small production cells needing local relay-switched outputs for contactors, solenoid valves, or indicator lamps alongside PROFINET connectivity to HMI panels and upstream SCADA.