- Description
The Siemens 6NH3112-3BA00-6XX1 is a plug-in extension board that adds HART and RS485 connectivity to the SIMATIC RTU3000C family, linking up to 16 Modbus RTU devices or 16 HART devices in multidrop mode for up to 32 variables. It transfers Modbus RTU data at 9600 to 115200 bit/s and HART at 1200 bit/s, draws power internally from the RTU, and operates from -40 to +60 °C in vertical or -40 to +70 °C in horizontal installation.
Technical Specifications
| SKU | 6NH3112-3BA00-6XX1 |
| Brand | Siemens |
| Series | SIMATIC RTU3000C |
| Product Type | Extension Board HART/RS485 |
| Connected Devices | 16 Modbus RTU devices or 16 HART devices in multidrop mode, max. 32 variables |
| RS 232 Transfer Rate | 9600 to 115200 bit/s |
| HART Transfer Rate | 1200 bit/s |
| Interface Connection | 6-pin plug-in terminal strip |
| Power Supply | Internal, via RTU3000C |
| Output Voltage, External Devices | DC 12 V or 24 V |
| Digital Output Current | 300 mA, limiting continuous current |
| Ambient Temperature, Vertical Installation / Operation | -40 to +60°C |
| Ambient Temperature, Horizontal Installation / Operation | -40 to +70°C |
| Ambient Temperature, Storage | -40 to +70°C |
| Ambient Temperature, Transport | -40 to +70°C |
| Relative Humidity (at 30°C, non-condensing, max) | 95 percent |
| Protection Class | IP20; IP68 with protective housing (see accessories) |
| Module Format | Plug-in module |
| Width | 38 mm |
| Height | 62 mm |
| Depth | 21 mm |
| Net Weight | 0.022 kg |
| Max. RS485 Wire Length | 30 m |
| Supported Protocols | Modbus RTU, HART (Multidrop) |
| HART Master Address Range | 0 to 63 |
| Modbus RTU Master Address Range | 1 to 247 |
| Configuration | Not required as a separate tool; configured via RTU3000C |
| Web-Based Diagnostics | Yes, over RTU3000C |
| Country of Origin | Germany |
Certifications & Standards
- CE
- UKCA
- RCM
- RoHS
- ATEX
- IECEx
- ULhazloc
- CCC
- FM
Selection Notes
Add the 6NH3112-3BA00-6XX1 when a low-power RTU3000C needs multidrop field wiring instead of point-to-point runs: one 6-pin terminal strip serves up to 16 Modbus RTU or 16 HART instruments, and the board draws its power from the RTU itself rather than a separate supply. Its ATEX, IECEx, ULhazloc, CCC, and FM approvals let it go into the same hazardous-location installations as the RTU3000C base unit.