- Home
- Communication & Fieldbus Modules
- Siemens 6GK7243-1BX30-0XE0 SIMATIC S7-1200 CP 1243-1 Ethernet Telecontrol Communication Processor Siemens 6GK7243-1BX30-0XE0 SIMATIC S7-1200 CP 1243-1 Ethernet Telecontrol Communication Processor
Siemens 6GK7243-1BX30-0XE0 SIMATIC S7-1200 CP 1243-1 Ethernet Telecontrol Communication Processor
Siemens 6GK7243-1BX30-0XE0 SIMATIC S7-1200 CP 1243-1 Ethernet Telecontrol Communication Processor
Get Quote
- Description
The Siemens 6GK7243-1BX30-0XE0 CP 1243-1 is a communication processor that adds a second Ethernet interface to a SIMATIC S7-1200 CPU and connects the station to a control center over telecontrol protocols including DNP3, IEC 60870-5, and TeleControl Basic, over a single 10/100 Mbit/s RJ45 port. It also provides a stateful-inspection firewall and IPsec VPN with up to 8 connections for secure remote access.
Technical Specifications
| SKU | 6GK7243-1BX30-0XE0 |
| Brand | Siemens |
| Series | SIMATIC S7-1200 |
| Product type designation | CP 1243-1 |
| Ethernet interface | 1x RJ45, 10-100 Mbit/s |
| Backplane supply | 5 V DC, 0.25 A typical |
| Power loss | 1.25 W |
| Operating temperature (vertical) | -20...+60 degrees C |
| Operating temperature (horizontal) | -20...+70 degrees C |
| Storage temperature | -40...+70 degrees C |
| Protection class | IP20 |
| Module format | Compact module S7-1200, single width |
| Dimensions (W x H x D) | 30 x 110 x 75 mm |
| Net weight | 0.122 kg |
| Max units per CPU | 3 |
| Telecontrol protocols | DNP3, IEC 60870-5, TeleControl Basic |
| Data buffering on connection loss | 64,000 events |
| Max data points per device | 500 |
| Cloud protocol | MQTT |
| Firewall type | Stateful inspection |
| VPN connections | 8, IPsec / SINEMA RC |
| VPN encryption | AES-256, AES-192, AES-128, 3DES-168 |
| VPN authentication | Preshared key (PSK), X.509v3 certificates |
| Time synchronization | NTP, NTP (secure) |
| Configuration software | STEP 7 Basic/Professional |
Certifications & Standards
- CE
- UKCA
- cULus
- RCM
- RoHS
- EAC
- ATEX
- IECEx
- CCC
- FM registration
Selection Notes
DNP3 and IEC 60870-5 support are what separate the CP 1243-1 from a standard S7-1200 integrated Ethernet port, so it is the module to add when a station must report to a SCADA control center over a recognized telecontrol protocol rather than plain TCP/IP. Up to 3 units per CPU allows redundant or multi-path reporting paths from a single controller. The 64,000-event data buffer means readings keep accumulating during a connection outage instead of being lost, which matters for unattended remote sites with intermittent links. Eight concurrent IPsec VPN connections with AES-256 support secure remote engineering access without a separate VPN appliance.
Applications
Remote telecontrol reporting from pump stations, substations, and unmanned sites to a SCADA control center via DNP3 or IEC 60870-5; secure VPN-based remote access and diagnostics for distributed S7-1200 installations; MQTT connectivity to cloud platforms.