- Schneider Electric GV2LE03 TeSys Deca Magnetic 3P 0.4 A 100 kA Motor Protection Circuit Breaker (MPCB) Schneider Electric GV2LE03 TeSys Deca Magnetic 3P 0.4 A 100 kA Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV2LE03 TeSys Deca Magnetic 3P 0.4 A 100 kA Motor Protection Circuit Breaker (MPCB)
Schneider Electric GV2LE03 TeSys Deca Magnetic 3P 0.4 A 100 kA Motor Protection Circuit Breaker (MPCB)
Get Quote
- Description
The Schneider Electric GV2LE03 is a TeSys Deca motor circuit breaker with magnetic-only protection, rated 0.4 A and 100 kA Icu at 400/415 V across 3 poles. It trips on short circuit at roughly 13x its rated current and gives manual isolation and start-stop control through a toggle, leaving thermal overload protection to a separate LRD relay.
Technical Specifications
| Reference | GV2LE03 |
| Brand | Schneider Electric |
| Range | TeSys Deca |
| Product Type | Motor circuit breaker |
| GTIN | 3389110516869 |
| Trip Unit Technology | Magnetic |
| Poles | 3P |
| Utilisation Category | Category A, AC-3, AC-3e |
| Line Rated Current | 0.4 A |
| Breaking Capacity (Icu) at 400/415 V | 100 kA |
| [Ue] Rated Operational Voltage | 690 V AC, 50/60 Hz |
| [Ui] Rated Insulation Voltage | 690 V |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV |
| Control Type | Toggle |
| Standard Motor Power at 400/415 V | 0.06-0.09 kW |
| Suitability for Isolation | Yes |
| Rated Duty | Uninterrupted |
| Connections - Terminals | Screw clamp terminal, 1...6 mm² |
| Fixing Mode | 35 mm DIN rail (clipped) or panel (adaptor plate) |
| IP Degree of Protection | IP20 |
| Ambient Air Temperature for Operation | -20...60 °C |
| Dimensions (H x W x D) | 89 x 45 x 78.5 mm |
| Net Weight | 0.33 kg |
| Units per Package | 24 |
Certifications & Standards
- CE
- UKCA
- cULus
- CCC
- EAC
- EN/IEC 60947-2
- EN/IEC 60947-4-1
Selection Notes
Use the GV2LE03 where the motor branch already has separate thermal overload protection (an LRD relay) and the circuit breaker only needs to clear short circuits — the magnetic-only trip unit has no adjustable thermal range, so it will not protect the motor against sustained overcurrent on its own. The toggle gives 100,000 AC-3 start-stop cycles, matching GV2 siblings that add thermal-magnetic protection (GV2ME/GV2P) in the same frame size. Fixed magnetic tripping also means the GV2LE03 does not need re-setting when the motor is changed for one of a similar locked-rotor current, unlike an adjustable thermal dial.