- Home
- Industrial Motors
- Siemens 1PH8286-1AF10-2BU2 SIMOTICS M-1PH8 Compact Asynchronous Motor 250kW 1500 r/min IP55 Siemens 1PH8286-1AF10-2BU2 SIMOTICS M-1PH8 Compact Asynchronous Motor 250kW 1500 r/min IP55
Siemens 1PH8286-1AF10-2BU2 SIMOTICS M-1PH8 Compact Asynchronous Motor 250kW 1500 r/min IP55
Siemens 1PH8286-1AF10-2BU2 SIMOTICS M-1PH8 Compact Asynchronous Motor 250kW 1500 r/min IP55
Get Quote
- Description
The Siemens 1PH8286-1AF10-2BU2 is a SIMOTICS M-1PH8 compact asynchronous motor rated 250 kW and 1592 Nm at 1500 r/min, extending to 310 kW at 2000 r/min in the field-weakening range. Built to IP55 with forced ventilation (NDE to DE), it has a 280 mm shaft height, carries a Pt1000 temperature sensor with no encoder, and weighs 1400 kg.
Technical Specifications
| Catalog No | 1PH8286-1AF10-2BU2 |
| Brand | Siemens |
| Series | SIMOTICS M-1PH8 |
| Product type | Compact asynchronous motor |
| Shaft height | 280 mm |
| Degree of protection | IP55 |
| Cooling | Forced ventilation, air flow NDE to DE |
| Mounting | IM B3 (IMV6) |
| S1 rating (BLM/SLM) at 400V supply | 1500 r/min, 250 kW, 1592 Nm, 490 A, 345 V |
| Field-weakening rating (ALM) at 400V supply | 1750 r/min, 270 kW, 1474 Nm, 460 A, 400 V |
| S1 rating (BLM/SLM) at 480V supply | 2000 r/min, 310 kW, 1481 Nm, 460 A, 455 V |
| Field-weakening rating (ALM) at 480V supply | 279 kW, 1211 Nm, 395 A, 500 V |
| Encoder | None (Pt1000 temperature sensor fitted) |
| Thermal time constant | 50 min |
| Moment of inertia | 52,000 kgcm2 |
| Weight | 1,400 kg |
| Terminal box designation | 1XB7700-P02 |
| Min. cooling air flow | 0.42 m3/s |
| Noise level (external fan, 50 Hz) | 74 dB |
| Pressure drop | 600 Pa |
| Color | Anthracite (RAL 7016) |
Selection Notes
The IP55 enclosure and forced ventilation on the 1PH8286-1AF10-2BU2 suit installations with dust, moisture, or washdown exposure that an open-circuit-cooled winding in the same 280 mm frame cannot tolerate. Continuous output is 250 kW at 1500 r/min, rising to 310 kW once the field-weakening range is reached on a 480 V supply. Its 50-minute thermal time constant gives more margin against transient overload than the shorter time constant typical of an open-circuit-ventilated sibling in the same frame. The 1500 r/min base speed suits higher-speed loads better than the 1000 r/min winding available in the same frame.