- Home
- HMI Accessories
- Siemens 6AV7674-1LA51-0AA0 SIMATIC HMI Extension Unit 19-inch Hardwired IP65 24V DC HMI Extension Unit Siemens 6AV7674-1LA51-0AA0 SIMATIC HMI Extension Unit 19-inch Hardwired IP65 24V DC HMI Extension Unit
Siemens 6AV7674-1LA51-0AA0 SIMATIC HMI Extension Unit 19-inch Hardwired IP65 24V DC HMI Extension Unit
Siemens 6AV7674-1LA51-0AA0 SIMATIC HMI Extension Unit 19-inch Hardwired IP65 24V DC HMI Extension Unit
Get Quote
- Description
The Siemens 6AV7674-1LA51-0AA0 is a 19-inch hardwired extension unit for SIMATIC HMI panels, adding 10 mountable control-element slots to any fully IP65-enclosed 16:9 HMI or IPC PRO device. Control elements wire in directly through 12-pin LED and 16-pin contact connectors instead of a network link, and the unit runs on a 24V DC supply drawing only 10 mA with no load attached.
Technical Specifications
| MLFB / Order Number | 6AV7674-1LA51-0AA0 |
| Brand | Siemens |
| Series | SIMATIC HMI |
| Product Designation | Extension Unit 19-inch hardwired |
| Mounting | Lower part of a 16:9 HMI/IPC PRO device, screwed joint |
| Command/Signal Element Slots | 10, max. 8 control elements plus 1 emergency stop button |
| LED Module Connector | 12-pin |
| Control Element Contact Connector | 16-pin |
| Emergency-Stop Contact Connector | 8-pin |
| Supply Voltage | 24V DC (19.2-28.8V DC) |
| Current Consumption | 10 mA, without load |
| Active Power Input | 0.1 W |
| Emitted Active Power | 5 W, max. with lamp load |
| Degree of Protection | IP65 all-round, NEMA Type 4 at the front |
| Suitable for Safety Functions | Yes, e.g. emergency stop installation |
| Ambient Temperature, Operation | 0 to 50 degrees C |
| Ambient Temperature, Storage/Transport | -20 to 60 degrees C |
| Installation Altitude, max. | 2000 m above sea level |
| Relative Humidity, Operation | max. 90 percent, no condensation |
| Max. Cable Length | 30 m |
| Enclosure Material | Aluminum, front knockout covered with black film |
| Dimensions (W x H x D) | 462 x 99 x 100.65 mm |
| Weight | 2.7 kg, without packaging |
| Delivery Quantity | 1 piece, incl. all connectors required for customer interfaces |
Certifications & Standards
- CE
- UL
- cULus
- RCM
- KC
Selection Notes
Hardwiring each of the 10 control-element positions through the 12-pin LED and 16-pin contact connectors avoids any dependency on the panel's network link, at the cost of running discrete cable back to the controller for every pushbutton and lamp. Its 10 mA draw is a fraction of the PROFINET variant's 150 mA, which matters on 19-inch panels already tight on 24V DC budget. Pick the PROFINET version instead when the control elements should report status over the network rather than through hardwired I/O.