- Home
- DIN Rail Power Supplies (24V DC)
- Siemens 6EP3344-0SB00-0AY0 SITOP PSU100E 48V 5A 1AC Power Supply Siemens 6EP3344-0SB00-0AY0 SITOP PSU100E 48V 5A 1AC Power Supply
Siemens 6EP3344-0SB00-0AY0 SITOP PSU100E 48V 5A 1AC Power Supply
Siemens 6EP3344-0SB00-0AY0 SITOP PSU100E 48V 5A 1AC Power Supply
Get Quote
- Description
The Siemens SITOP PSU100E 6EP3344-0SB00-0AY0 is a single-phase AC power supply rated 100/230 V AC input and 48 V DC/5 A output, delivering 240 W at 92% efficiency with a 30 ms buffering time on power loss. Output voltage is adjustable from 48 to 54 V via potentiometer, and two units can be paralleled for higher power.
Technical Specifications
| SKU | 6EP3344-0SB00-0AY0 |
| Brand | Siemens |
| Series | SITOP PSU100E |
| Product designation | PSU100E, 48V/5A |
| Input type | 1-phase AC |
| Input voltage range 1 | 85 ... 132 V AC |
| Input voltage range 2 | 170 ... 264 V AC |
| Line frequency | 47 ... 63 Hz |
| Buffering time, min., rated output | 30 ms |
| Input current at 120V | 4.4 A |
| Input current at 230V | 2 A |
| Inrush current, max., at 25°C | 58 A |
| Output voltage (rated) | 48 V DC |
| Adjustable output range | 48 ... 54 V, max. 240 W |
| Voltage tolerance | 3% |
| Residual ripple, max. | 50 mV |
| Output current (rated) | 5 A |
| Output power, typ. | 240 W |
| Efficiency | 92% |
| Power loss, typ. | 12 W |
| Short-circuit protection | Electronic shutdown, automatic restart |
| Galvanic isolation | Yes, SELV/ES1 (IEC 62368-1), DVC As (IEC 61204-7) |
| Protection class | Class I |
| Protection class IP | IP20 |
| Operating temperature | -25 ... +70 °C |
| Storage/transport temperature | -40 ... +85 °C |
| MTBF at 40°C | 1,050,000 h |
| Enclosure (W x H x D) | 42 x 125 x 125 mm |
| Mounting | Snaps onto DIN rail EN 60715 35x7.5/15 |
| Net weight | 0.5 kg |
Certifications & Standards
- CE
- EAC
Selection Notes
The 48 V/5 A output and 240 W rating fit loads that a standard 24 V SITOP supply can't serve directly - DC motor brakes, some sensor/actuator networks, or auxiliary control circuits specified at 48 V. Two units can be connected in parallel to raise available power beyond 240 W, which is the path to take if a single 5 A output is undersized rather than switching to a different SITOP series. The 85-132 V and 170-264 V dual input range auto-covers both 120 V and 230 V mains without a selector switch.
Applications
Used where 48 V DC is the plant standard - telecom-adjacent equipment, some conveyor brake circuits, or auxiliary control loops - fed from single-phase 100-230 V AC mains.