The Siemens 6EP4145-8GB00-0XY0 is a SITOP BAT8600 lead-acid battery module that stores 380 W-h at 48 V DC for the SITOP UPS8600 uninterruptible power system, delivering 20 A rated output current. Its maintenance-free sealed lead-acid cells bridge about 10 minutes at a 960 W system load, and up to five modules can be paralleled to extend backup time.
Technical Specifications
| SKU | 6EP4145-8GB00-0XY0 |
| Brand | Siemens |
| Series | SITOP BAT8600 |
| EAN | 4025515155089 |
| Product Designation | Battery module 380 Wh |
| Battery Type | Maintenance-free lead-acid batteries |
| Energy Content | 380 W-h |
| Output Voltage | 48 V DC |
| Output Current, Rated | 20 A |
| Bridging Time at 960 W Load | typ. 10 min |
| Bridging Time at 480 W Load | typ. 25 min |
| Max Parallel Modules | 5 |
| Short-Circuit Protection | Blade-type fuse 40 A, 58 V DC |
| Overload Protection | Valve control |
| Display | 3-color LED for module operating state |
| Protection Class IP | IP20 |
| Operating Resource Protection Class | Class III |
| UL/cULus Approval | cULus (UL 61010-1 3rd Ed., UL 61010-2-201 2nd Ed.) |
| Ambient Temperature, Operation | -10 ... +50 C |
| Service Life at 10 C | typ. 8 a |
| Service Life at 20 C | typ. 4 a |
| Service Life at 30 C | typ. 2 a |
| Service Life at 40 C | typ. 1 a |
| Service Life at 50 C | typ. 0.5 a |
| Number of Batteries | 4 |
| Enclosure W x H x D | 322 x 187 x 110 mm |
| Mounting | Wall mounting, keyhole for M4 screws |
| Net Weight | 13.5 kg |
Certifications & Standards
- CE
- EAC
- CB
- Shipbuilding
- ABS
- DNV
- EPD
Selection Notes
Service life on this chemistry drops off faster with heat than a typical DIN-rail accessory: 8 years at 10 C falls to just 6 months at 50 C, so placement away from heat-generating equipment is the main lever for reaching the rated life. At a 960 W system load the module bridges about 10 minutes; at 480 W that stretches to 25 minutes, a useful reference when matching bridging time to the actual downstream load rather than the full 40 A system rating. Up to five BAT8600 modules can be paralleled on the same UPS8600 bus to extend runtime without adding a separate charger.