Siemens 6EP1931-2DC31 SITOP DC UPS Module 24V/6A DIN Rail Serial Interface
Siemens 6EP1931-2DC31 SITOP DC UPS Module 24V/6A DIN Rail Serial Interface
Get Quote
- Description
The Siemens 6EP1931-2DC31 is a SITOP DC UPS module that buffers a 24 V DC bus at 6 A and adds a serial PC interface for status monitoring, drawing 24 V/6.85 A on the input side to power the load and charge an external battery module at the same time. It mounts on a 50 mm-wide DIN rail and switches to battery backup at an adjustable 22-25.5 V threshold with a 1 s startup delay when the incoming supply drops.
Technical Specifications
| Order Number | 6EP1931-2DC31 |
| Brand | Siemens |
| Series | SITOP DC |
| Product Designation | DC UPS |
| Input Voltage DC | 24 V rated (22...29 V range) |
| Input Current | 6 A rated (plus approx. 0.6 A with empty battery) |
| Buffer Threshold (adjustable) | 22...25.5 V in 0.5 V steps, preset 22.5 V |
| Output Voltage | 24 V DC, normal and buffering mode (Vin minus approx. 0.5 V) |
| Output Current | 6 A rated (0...6 A, normal and buffering mode) |
| Peak Current | 6.3 A |
| Startup Delay | 1 s typical |
| Voltage Rise Time | 60 ms typical |
| Efficiency | 95% normal operation, 94.5% on battery |
| Power Loss | 7 W typical (normal), 8 W typical (on battery) |
| Supplied Active Power | 144 W typical |
| Charging Current | 0.2 A / 0.4 A |
| Interface | Serial, PC interface |
| Protection | Reverse polarity (input and battery), output short-circuit proof |
| Protection Class | IP20 / Class III |
| Ambient Temperature (operation) | -25...+60C |
| Enclosure Dimensions (WxHxD) | 50 x 125 x 125 mm |
| Mounting | DIN rail EN 60715 35x7.5/15 |
| Net Weight | 0.45 kg |
| MTBF | 966,183 h at 40C |
| Country of Origin | RO |
Certifications & Standards
- CE
- EAC
- Shipbuilding
- ABS
- DNV
- EPD
Selection Notes
The serial PC interface is the difference from the no-interface model in the same SITOP DC UPS pair: it lets a PC or PLC read battery status and buffering state directly instead of relying only on the floating relay contacts (Bat/OK and Alarm/Bat) for a lamp or digital input. The buffer threshold is adjustable from 22 to 25.5 V in 0.5 V steps, letting the switchover point be set above the normal supply's minimum tolerance so the module engages before a marginal PLC power dip. At 6 A output it draws 6.85 A on the input to power the load and charge the battery at the same time, so the upstream 24 V supply needs headroom beyond the 6 A load current.