Filter

Circuit Breakers & Protection Categories

Circuit Breakers & Protection

Filter
Showing 1 - 1940 of 3484 items

Schneider Electric A9F84350 iC60H 3P 50A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84350
Rated Current (A): 50
Number of Poles: 3P
82 pcs in stock
$62.94

Schneider Electric A9F84332 iC60H 3P 32A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84332
Rated Current (A): 32
Number of Poles: 3P
100 pcs in stock
$44.25

Schneider Electric A9F84320 iC60H 3P 20A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84320
Rated Current (A): 20
Number of Poles: 3P
37 pcs in stock
$42.32

Schneider Electric A9F84316 iC60H 3P 16A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84316
Rated Current (A): 16
Number of Poles: 3P
100 pcs in stock
$42.32

Schneider Electric A9F84310 iC60H 3P 10A Miniature Circuit Breaker Acti 9

Reference No: A9F84310
Rated Current (A): 10
Number of Poles: 3P
84 pcs in stock
$42.32

Schneider Electric A9F84306 iC60H 3P 6A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84306
Rated Current (A): 6
Number of Poles: 3P
27 pcs in stock
$42.32

Schneider Electric A9F84304 iC60H 3P 4A Miniature Circuit Breaker Acti 9

Reference No: A9F84304
Rated Current (A): 4
Number of Poles: 3P
22 pcs in stock
$52.10

Schneider Electric A9F84303 iC60H 3P 3A Miniature Circuit Breaker Acti 9

Reference No: A9F84303
Rated Current (A): 3
Number of Poles: 3P
7 pcs in stock
$52.10

Schneider Electric A9F84263 iC60H 2P 63A Acti9 Miniature Circuit Breaker

Reference No: A9F84263
Rated Current (A): 63
Number of Poles: 2P
19 pcs in stock
$64.87

Schneider Electric A9F84250 iC60H 2P 50A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84250
Rated Current (A): 50
Number of Poles: 2P
2 pcs in stock
$54.57

Schneider Electric A9F84225 iC60H 2P 25A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84225
Rated Current (A): 25
Number of Poles: 2P
70 pcs in stock
$30.29

Schneider Electric A9F84220 iC60H 2P 20A Miniature Circuit Breaker

Reference No: A9F84220
Rated Current (A): 20
Number of Poles: 2P
34 pcs in stock
$30.29

Schneider Electric A9F84216 iC60H 2P 16A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84216
Rated Current (A): 16
Number of Poles: 2P
100 pcs in stock
$30.29

Schneider Electric A9F84210 iC60H 2P 10A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84210
Rated Current (A): 10
Number of Poles: 2P
100 pcs in stock
$30.29

Schneider Electric A9F84206 iC60H 2P 6A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84206
Rated Current (A): 6
Number of Poles: 2P
90 pcs in stock
$30.29

Schneider Electric A9F84203 iC60H 2P 3A 10kA Miniature Circuit Breaker Acti9

Reference No: A9F84203
Rated Current (A): 3
Number of Poles: 2P
5 pcs in stock
$34.91

Schneider Electric A9F84202 iC60H 2P 2A Miniature Circuit Breaker Acti9 DIN Rail MCB

Reference No: A9F84202
Rated Current (A): 2
Number of Poles: 2P
83 pcs in stock
$34.91

Schneider Electric A9F84201 iC60H 2P 1A 70kA Miniature Circuit Breaker Acti9

Reference No: A9F84201
Rated Current (A): 1
Number of Poles: 2P
7 pcs in stock
$34.91

Schneider Electric A9F84170 iC60H 1P 0.5A Miniature Circuit Breaker

Reference No: A9F84170
Rated Current (A): 0.5
Number of Poles: 1P
6 pcs in stock
$16.01

Schneider Electric A9F84150 iC60H 1P 50A Miniature Circuit Breaker DIN Rail MCB

Reference No: A9F84150
Rated Current (A): 50
Number of Poles: 1P
27 pcs in stock
$18.79

Circuit breakers and protection devices from ABB, Siemens, Schneider Electric and Mersen cover the full low-voltage protection chain, from miniature circuit breakers to air circuit breakers up to 6300 A. The range includes MCB, MCCB, ACB, residual current devices, arc fault detection devices and surge protective devices in 1 to 4 poles, with more than 4,500 listed products. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Rated current and pole count, matched to the load and the neutral arrangement.
  • Breaking capacity at the installation voltage, at or above the prospective short-circuit current.
  • Standard: IEC 60898-1 for household and similar MCBs, IEC 60947-2 for industrial breakers, IEC 61008 and 61009 for RCDs.
  • Trip characteristic or trip unit type, and coordination with upstream and downstream devices.

FAQ

What is the difference between an MCB and an MCCB?

An MCB is a DIN-rail breaker for final circuits, usually with fixed thermal-magnetic tripping. An MCCB covers higher currents and short-circuit levels and often has adjustable or electronic trip units.

Do I need an RCD in addition to a circuit breaker?

Yes, where earth-leakage protection is required. A standard breaker protects against overload and short circuit, while an RCD detects leakage current to earth.

Can you ship circuit breakers outside Turkey?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.