- Home
- All Collections
- Circuit Breakers & Protection
Circuit Breakers & Protection
Circuit Breakers & Protection Categories
Circuit Breakers & Protection
Schneider Electric A9N18367 C120N 3P 100A 10kA Miniature Circuit Breaker Acti9
Schneider Electric A9N18365 C120N 3P 80A 10kA Miniature Circuit Breaker
Schneider Electric A9N18359 C120N 1-Pole 125A Miniature Circuit Breaker
Schneider Electric A9N18358 C120N 1P 100A Miniature Circuit Breaker
Schneider Electric A9N18357 C120N 1P 80A Miniature Circuit Breaker
Schneider Electric A9R61463 iID 4P 63A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R61425 iID 4P 25A Residual Current Circuit Breaker Acti 9 Series
Schneider Electric A9R61240 iID 2P 40A Residual Current Circuit Breaker (RCCB) Acti 9
Schneider Electric A9R61225 iID 2P 25A Residual Current Circuit Breaker (RCCB) Acti 9
Schneider Electric A9R44463 iID 4P 63A Residual Current Circuit Breaker (RCCB) Acti9
Schneider Electric A9R44440 iID 4P 40A Residual Current Circuit Breaker (RCCB) Acti 9
Schneider Electric A9R44425 iID 4P 25A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R44263 iID 2P 63A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R44240 iID 2P 40A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R44225 iID 2P 25A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R41463 iID 4P 63A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R41440 iID 4P 40A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R41425 iID 4P 25A 10kA 400/415V AC Earth Leakage Protection RCCB DIN Rail
Schneider Electric A9R41263 iID 2P 63A Residual Current Circuit Breaker (RCCB) Acti9
Schneider Electric A9R41240 iID 2P 40A Residual Current Circuit Breaker Acti 9
Circuit breakers and protection devices from ABB, Siemens, Schneider Electric and Mersen cover the full low-voltage protection chain, from miniature circuit breakers to air circuit breakers up to 6300 A. The range includes MCB, MCCB, ACB, residual current devices, arc fault detection devices and surge protective devices in 1 to 4 poles, with more than 4,500 listed products. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Miniature Circuit Breakers (MCB) – DIN-rail overcurrent protection for final circuits and distribution boards.
- Molded Case Circuit Breakers (MCCB) – feeder and motor-circuit protection with adjustable trip units.
- Air Circuit Breakers (ACB) – main incomer and bus-tie breakers from 630 A to 6300 A.
- Residual Current Devices (RCD) – earth-leakage protection against shock and fire.
- Arc Fault Detection Devices (AFDD) – detection of series and parallel arcs in final circuits.
- Surge Protective Devices (SPD) – protection of installations against transient overvoltage.
How to choose
- Rated current and pole count, matched to the load and the neutral arrangement.
- Breaking capacity at the installation voltage, at or above the prospective short-circuit current.
- Standard: IEC 60898-1 for household and similar MCBs, IEC 60947-2 for industrial breakers, IEC 61008 and 61009 for RCDs.
- Trip characteristic or trip unit type, and coordination with upstream and downstream devices.
FAQ
What is the difference between an MCB and an MCCB?
An MCB is a DIN-rail breaker for final circuits, usually with fixed thermal-magnetic tripping. An MCCB covers higher currents and short-circuit levels and often has adjustable or electronic trip units.
Do I need an RCD in addition to a circuit breaker?
Yes, where earth-leakage protection is required. A standard breaker protects against overload and short circuit, while an RCD detects leakage current to earth.
Can you ship circuit breakers outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.