- Schneider Electric C40F31M320 ComPacT NSX400F 3P 320 A 36 kA MicroLogic 1.3 M Moulded Case Circuit Breaker Schneider Electric C40F31M320 ComPacT NSX400F 3P 320 A 36 kA MicroLogic 1.3 M Moulded Case Circuit Breaker
Schneider Electric C40F31M320 ComPacT NSX400F 3P 320 A 36 kA MicroLogic 1.3 M Moulded Case Circuit Breaker
Schneider Electric C40F31M320 ComPacT NSX400F 3P 320 A 36 kA MicroLogic 1.3 M Moulded Case Circuit Breaker
Get Quote
- Description
The Schneider Electric C40F31M320 is a 3-pole ComPacT NSX400F moulded case circuit breaker for motor protection, rated 320 A on a MicroLogic 1.3 M electronic trip unit with a short-time (S) and instantaneous (I) electronic trip, with no built-in long-time overload function. Breaking capacity (Icu) is 36 kA at 380/415 V AC, with a 690 V AC rated operational voltage.
Technical Specifications
| Reference | C40F31M320 |
| Brand | Schneider Electric |
| Range | ComPacT |
| Device Short Name | NSX400F |
| Product Type | Circuit breaker |
| Device Application | Motor protection |
| Poles | 3P |
| Protected Poles | 3D |
| [In] Rated Current | 320 A at 65 °C |
| [Ue] Rated Operational Voltage | 690 V AC 50/60 Hz |
| [Ui] Rated Insulation Voltage | 800 V AC |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Breaking Capacity [Icu] at 380/415 V AC | 36 kA (IEC 60947-2) |
| Trip Unit | MicroLogic 1.3 M, electronic |
| Trip Unit Protection Functions | S (short-time) + I (instantaneous) |
| [Isd] Short-Time Pick-up Settings | 1600 / 1920 / 2440 / 2560 / 2880 / 3200 / 3520 / 3840 / 4160 A (9 fixed steps) |
| [Ii] Instantaneous Pick-up | 4800 A (fixed) |
| Suitability For Isolation | Yes (EN/IEC 60947-2) |
| Zone Selective Interlocking (ZSI) | Without |
| Mounting Mode | Fixed |
| Connection | Front (upside and downside) |
| Dimensions (W x H x D) | 140 x 255 x 110 mm |
| Net Weight | 6.05 kg |
| IP Degree Of Protection | IP40 (IEC 60529) |
| Ambient Air Temperature For Operation | -25...70 °C |
Certifications & Standards
- EN/IEC 60947-2
Selection Notes
The MicroLogic 1.3 M trip unit gives this NSX400F It provides no thermal overload (L) function of its own, so it is paired with a separate motor overload relay for thermal protection; use it where short-circuit and short-time protection is wanted ahead of a motor starter that already has its own overload device. At 36 kA Icu, the F-frame breaking capacity sets how close to the transformer the breaker can sit; choose the 2.3 M sibling in the same frame when the opposite combination of built-in overload and trip-class control is needed.