Part number
PAS800
2,647.46 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric PAS800 EcoStruxure Panel Server Advanced Data Logger Energy Server Communication Gateway

EcoStruxure Panel Server Advanced gateway, 3-year data logger, energy server, 110-277 V AC/DC, DIN rail.

Rated operational voltage
110–277–DC V DC
Communication
2x Ethernet RJ45, RS485, Modbus TCP/RTU, Wi-Fi, IEEE 802.15.4
EAN
3606481014375
Description

About the PAS800

The Schneider Electric PAS800 EcoStruxure Panel Server Advanced is a gateway and energy server that connects wired Modbus devices and wireless PowerTag sensors while logging three years of historical data onboard. It bridges up to 32 Modbus RTU and 128 Modbus TCP/IP devices, plus up to 85 wireless IEEE 802.15.4 devices, powered from a 110-277 V AC/DC supply.

Certifications & Standards

  • CE
  • cULus
  • CB
  • RCM
  • UKCA
  • FCC
  • IEC 61010-1
  • UL 61010-1
  • IEC 62974-1
  • IEC 61326-1

Selection Notes

The PAS800 adds a 3-year onboard data logger with historical dashboarding, trending and CSV export on top of the PAS600's live-monitoring gateway, which matters when the panel needs to answer "what happened here" months later without relying on an external data historian. Its 32-64 GB eMMC memory (versus the PAS600's 512 MB-32 GB) is what makes that retention possible. Choose the plain PAS600 instead when only real-time pass-through to an existing BMS/SCADA system is needed and local history is not required.

Specification

Full specification

61 values · Last verified 30 Oct 2026

Main 7

Range EcoStruxure
Product name Panel Server Advanced
Product or Component Type Gateway
Device short name PAS800
Device Application Gateway & energy server, Data logger
[Us] rated supply voltage 110...277 V AC 50/60 Hz, 110...277 V DC
Communication gateway Ethernet TCP/IP to wireless devices, Ethernet/serial

Complementary 35

Product Compatibility Wireless access point
Maximum power consumption in W 3.5 W 110...277 V
Maximum power consumption in VA 12 VA at 110...277 V
Communication network type Wi-Fi infrastructure5 GHz, Wi-Fi infrastructure2.4 GHz, Ethernet 10/100BASE-T, Wi-Fi access point2.4 GHz, Wireless IEEE 802.15.4, Modbus RTU Modbus RTU client even/odd or none parity 1.2...115.2 kbit/s
Communication port protocol Modbus TCP, DHCP, HTTPS, NTP/SNTP, IPv4, IPv6, TCP/IP
Communication port support 2 RJ45 ETHERNET, Screw terminal block RS485
Number of server device(s) 32 Modbus RTU product(s), 128 Modbus TCP/IP product(s), 40 wireless (IEEE 802.15.4) product(s) - mixed, 85 wireless (IEEE 802.15.4) product(s) - depending on configuration
Number of devices 64 Modbus TCP/IP
Memory capacity HW V2: 64 GB eMMC, HW V1: 32 GB eMMC, HW V1: 512 MB NAND
Number of inputs 0
Connections - terminals Power supply screw terminal block top) 0.002…0.004 in² (1.5…2.5 mm²), Communication screw terminal block bottom) 0.0002…0.002 in² (0.14…1.5 mm²)
Tightening torque Power supply: 5.3 lbf.in (0.6 N.m), Communication: 2.21 lbf.in (0.25 N.m)
Wire stripping length Power supply: 0.3 in (7 mm), Communication: 0.3 in (7 mm)
Number of connectors 2 screw connector for Wi-Fi and IEEE 802.15.4
Connector type connector(s)1 x RP-SMA Wi-Fi for antenna bottom, connector(s)1 x RP-SMA IEEE 802.15.4 for antenna top
Mounting Mode Clip-on
Mounting Support DIN rail
Product Certifications CE, cULus, CB, RCM, UKCA, FCC, IC, DNV Marine, ANSI RF, IACS E10
Standards IEC 61010, IEC 61010-1, IEC 61010-2-201, UL 61010, UL 61010-1, UL 61010-2-201, EN 61010-1, EN 61010-2-201, CAN/CSA C22.2 No. 61010-1-12, CAN/CSA C22.2 No. 61010-2-201, IEC 62974-1, IEC 61326-1, EN 61326-1, ETSI EN 301 489-1, ETSI EN 301 489-17, EN 301-893, EN 55032, CISPR 11, ETSI EN 300 328, IEEE 802.15.4, IEEE 802.11a/b/g/n, IEEE 802.3 af/at, FCC CFR 47 part 15 class A, EN 62311, IEC 62311, IEC 60945, EN 62974-1
Depth 2.8 in (70.2 mm)
Height 3.7 in (93 mm)
Width 2.8 in (72 mm)
Net Weight 7.3 oz (206 g)
Data recording Historical dashboarding and trending, 3 years data logs
Data buffer for data publication (cloud, SFTP, HTTPS) depending on network 3 month(s)
Function Available Embedded web page for configuration and upgrade, Diagnosis capabilities, Diagnostic report, Diagnostics on communication, Embedded data logger, Event Logger, Energy management, With integrated web server, Firmware update, Configurable event, Backup/restore configuration, CSV export
Product Specific Application Wireless Schneider Electric devices ecosystem
Topology Separated Ethernet network, Switched Ethernet network
Web services HTTPS server, SFTP publication (CSV / JSON), HTTPS publication (CSV / JSON), Alarm notification by e-mail
Communication Service Device Profile for Web Services (DPWS), Modbus TCP client, Modbus TCP server, SNTP client, DHCP client, Web server (energy & operation efficiency), RSTP
Commissioning interface EcoStruxure Power Commission desktop, EcoStruxure Power Commission Mobile (through Wi-Fi Access point), EcoStruxure Power Commission web (for third party device integration), Web page
Realtime clock With RTC-battery set, With user calibration
Time synchronisation protocol NTP, SNTP
Range compatibility EcoStruxure Facility Expert, EcoStruxure Building Operation, EcoStruxure Power Operation, EcoStruxure Power Monitoring Expert, EcoStruxure Asset Advisor, EcoStruxure Energy Hub, EcoStruxure Resource Advisor, Third party SCADA
Communication iinterface Modbus and wireless (IEEE802.15.4) product

Environment 6

Relative humidity 5…95 %
IP degree of protection IP40 front face), IP20 casing)
Ambient air temperature for operation -13…158 °F (-25…70 °C)
Ambient Air Temperature for Storage -40…185 °F (-40…85 °C)
Pollution degree 2
Operating altitude < 6561.68 ft (2000 m)
Show all 61 specifications ↓ Show less ↑13 more values in Identification, Contractual warranty, Logistics.

Identification 7

Part number PAS800
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3606481014375

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin IN
Shipping weight 0.206 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for PAS800

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • cULus
  • CE
  • UKCA
  • Marine
  • IEC 61010
  • IEC 61010-1
  • IEC 61010-2-201
  • UL 61010
  • UL 61010-1
  • UL 61010-2-201
  • EN 61010-1
  • EN 61010-2-201
  • CAN/CSA C22.2 No. 61010-1-12
  • CAN/CSA C22.2 No. 61010-2-201
  • IEC 62974-1
  • IEC 61326-1
Quick answers

Questions about the PAS800

Which supply voltage is PAS800 rated for?

The rated operational voltage of PAS800 is 110–277–DC V DC.

What is the HS code of PAS800 for customs?

The tariff (HS) code on file for PAS800 is 851762.

What is the EAN of PAS800?

The EAN (GTIN) of PAS800 is 3606481014375.

Where does PAS800 ship from, and how fast?

PAS800 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

2,647.46 SR On request
Get a Quote
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · PAS800

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart