Arc Fault Detection Devices (AFDD)
45 parts
Arc fault detection devices (AFDD) from ABB detect dangerous series and parallel arcs in final circuits and disconnect them before they start a fire. The range covers ABB S-ARC1 and DS-ARC1 in 1P+N from 6 A to 40 A, with integrated overcurrent protection or with overcurrent and residual current protection. Stoklink ships worldwide from Turkey and quotes on request.
45 parts
Showing 1–452CSA275103R1164 DS-ARC1 M C16 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · ABB DS-ARC1 M C16 A30 - 1P+N AFDD+RCBO, 16 A, Type A 30 mA, 3 DIN-rail modules.
2CSA275901R9204 S-ARC1 M C20ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M C20 AFDD with integrated 20A Type C MCB, 1P+N, 10kA breaking capacity (IEC 60898-1).
2CSA275103R1134 DS-ARC1 M C13 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · ABB DS-ARC1 M C13 A30 - 1P+N AFDD+RCBO, 13 A, Type A 30 mA, 3 DIN-rail modules.
2CSA275103R1104 DS-ARC1 M C10 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · ABB DS-ARC1 M C10 A30 - 1P+N AFDD+RCBO, 10 A, Type A 30 mA, 3 DIN-rail modules.
2CSA275103R1135 DS-ARC1 M B13 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 M B13 A30 AFDD with integrated RCBO, 1P+N, 13 A, curve B, 30 mA Type A, 10 kA breaking capacity, 3 DIN-rail modules.
2CSA275103R1105 DS-ARC1 M B10 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 M B10 A30 AFDD with integrated RCBO, 1P+N, 10 A, curve B, 30 mA Type A, 10 kA breaking capacity, 3 DIN-rail modules.
2CSA275103R1065 DS-ARC1 M B6 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 M B6 A30 AFDD with integrated RCBO, 1P+N, 6 A, curve B, 30 mA Type A, 10 kA breaking capacity, 3 DIN-rail modules.
2CSA275103R1064 DS-ARC1 M C6 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · ABB DS-ARC1 M C6 A30 - 1P+N AFDD+RCBO, 6 A, Type A 30 mA, 3 DIN-rail modules.
2CSA275103R1205 DS-ARC1 M B20 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 M B20 A30 AFDD with integrated RCBO, 1P+N, 20 A, curve B, 30 mA Type A, 10 kA breaking capacity, 3 DIN-rail modules.
2CSA275901R9164 S-ARC1 M C16ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M C16 AFDD with integrated 16A Type C MCB, 1P+N, 10kA breaking capacity (IEC 60898-1).
2CSA275901R9134 S-ARC1 M C13ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M C13 AFDD with integrated 13A Type C MCB, 1P+N, 10kA breaking capacity (IEC 60898-1).
2CSA275901R9135 S-ARC1 M B13ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M B13 AFDD with integrated 13A Type B MCB, 1P+N, 10kA breaking capacity (IEC 60898-1).
2CSA275901R9064 S-ARC1 M C6ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M C6 arc fault detection device with integrated MCB, 1P+N, 6 A, C curve, 10 kA breaking capacity, 2-module DIN-rail.
2CSA275901R9205 S-ARC1 M B20ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M B20 AFDD with integrated 20A Type B MCB, 1P+N, 10kA breaking capacity (IEC 60898-1).
2CSA275901R9165 S-ARC1 M B16ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M B16 AFDD with integrated 16A Type B MCB, 1P+N, 10kA breaking capacity (IEC 60898-1).
2CSA275901R9104 S-ARC1 M C10ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M C10 AFDD with integrated 10A Type C MCB, 1P+N, 10kA breaking capacity (IEC 60898-1).
2CSA275901R9065 S-ARC1 M B6ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M B6 AFDD with integrated 6A Type B MCB, 1P+N, 10kA breaking capacity (IEC 60898-1).
2CSA275901R9105 S-ARC1 M B10ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 M B10 AFDD with integrated 10A Type B MCB, 1P+N, 10kA breaking capacity (IEC 60898-1).
2CSA255103R1204 DS-ARC1 C20 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 C20 A30 AFDD with integrated RCBO, 1P+N, 20 A, curve C, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255103R1164 DS-ARC1 C16 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 C16 A30 AFDD with integrated RCBO, 1P+N, 16 A, curve C, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255103R1134 DS-ARC1 C13 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 C13 A30 AFDD with integrated RCBO, 1P+N, 13 A, curve C, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255103R1104 DS-ARC1 C10 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 C10 A30 AFDD with integrated RCBO, 1P+N, 10 A, curve C, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255103R1064 DS-ARC1 C6 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 C6 A30 AFDD with integrated RCBO, 1P+N, 6 A, curve C, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255103R1205 DS-ARC1 B20 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 B20 A30 AFDD with integrated RCBO, 1P+N, 20 A, curve B, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255103R1165 DS-ARC1 B16 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 B16 A30 AFDD with integrated RCBO, 1P+N, 16 A, curve B, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255103R1135 DS-ARC1 B13 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 B13 A30 AFDD with integrated RCBO, 1P+N, 13 A, curve B, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255103R1105 DS-ARC1 B10 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 B10 A30 AFDD with integrated RCBO, 1P+N, 10 A, curve B, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255103R1065 DS-ARC1 B6 A30ABB · Arc Fault Detection Devices with Integrated Overcurrent and Residual Current Protection - AFDD+RCBO · DS-ARC1 B6 A30 AFDD with integrated RCBO, 1P+N, 6 A, curve B, 30 mA Type A, 7.5 kA breaking capacity, 3 DIN-rail modules.
2CSA255901R9404 S-ARC1 C40ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 C40 AFDD with integrated 40A Type C MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9324 S-ARC1 C32ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 C32 AFDD with integrated 32A Type C MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9254 S-ARC1 C25ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 C25 AFDD with integrated 25A Type C MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9204 S-ARC1 C20ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 C20 AFDD with integrated 20A Type C MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9164 S-ARC1 C16ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 C16 AFDD with integrated 16A Type C MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9134 S-ARC1 C13ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 C13 AFDD with integrated 13A Type C MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9104 S-ARC1 C10ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 C10 AFDD with integrated 10A Type C MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9064 S-ARC1 C6ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 C6 AFDD with integrated 6A Type C MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9405 S-ARC1 B40ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 B40 AFDD with integrated 40A Type B MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9325 S-ARC1 B32ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 B32 AFDD with integrated 32A Type B MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
2CSA255901R9255 S-ARC1 B25ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 B25 1P+N arc fault detection device with integrated 25A curve-B MCB, 7.5kA breaking capacity, 2-module DIN-rail.
2CSA255901R9205 S-ARC1 B20ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 B20 1P+N arc fault detection device with integrated 20A curve-B MCB, 7.5kA breaking capacity, 2-module DIN-rail.
2CSA255901R9165 S-ARC1 B16ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 B16 1P+N arc fault detection device with integrated 16A curve-B MCB, 7.5kA breaking capacity, 2-module DIN-rail.
2CSA255901R9135 S-ARC1 B13ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 B13 1P+N arc fault detection device with integrated 13A curve-B MCB, 7.5kA breaking capacity, 2-module DIN-rail.
2CSA255901R9105 S-ARC1 B10ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 B10 1P+N arc fault detection device with integrated 10A curve-B MCB, 7.5kA breaking capacity, 2-module DIN-rail.
2CSA255901R9065 S-ARC1 B6ABB · Arc Fault Detection Devices with Integrated Overcurrent Protection - AFDD+MCB · ABB S-ARC1 B6 AFDD with integrated 6A Type B MCB, 1P+N, 6kA breaking capacity (IEC 60898-1).
Can't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
Arc Fault Detection Devices (AFDD) buying guide
What's in this range
- ABB S-ARC1: AFDD with integrated MCB function, B and C curves.
- ABB DS-ARC1: AFDD with integrated RCBO function, with 30 mA Type A versions.
- 1P+N devices for final circuits.
How to choose
- Function: AFDD+MCB for overcurrent only, AFDD+RCBO where leakage protection is also required.
- Rated current and curve: B or C, matched to cable and load.
- Breaking capacity: compare the kA value with the prospective fault current.
- Standard: IEC 62606 for AFDDs. Check which circuits your local wiring rules require to be protected.
Arc Fault Detection Devices (AFDD) questions
What does an AFDD protect against that an MCB does not?
An MCB reacts to overload and short circuit. An AFDD analyzes the current waveform and trips on arcing faults that stay below the MCB threshold.
Do I still need an RCD with an AFDD?
Yes, unless the device is an AFDD+RCBO type, which includes residual current protection.
Can you supply AFDDs outside Turkey?
Yes. Stoklink ships worldwide from Turkey, EXW. Availability depends on the distributor, so request a quote to confirm.