RCBO (Residual Current Breakers with Overcurrent Protection)
97 parts
RCBOs (residual current breakers with overcurrent protection) from Siemens, ABB and Schneider Electric combine earth leakage, overload and short-circuit protection in one DIN-rail device. The range covers 6 A to 40 A in 1+N, 2, 3 and 4 poles, mainly Siemens 5SU1 plus ABB DS201 and Schneider Electric Acti9 iDPN N Vigi. Stoklink ships worldwide from Turkey.
97 parts
Showing 1–485SV6016-7KK32 5SV6Siemens · 5SV6 32A 2P 230V Residual Current Device
5SV6016-7KK20 5SV6Siemens · 5SV6 20A 2P 230V Residual Current Device
5SV6016-7KK25 5SV6Siemens · 5SV6 25A 2P 230V Residual Current Device
5SV6016-7KK10 5SV6Siemens · 5SV6 10A 2P 230V Residual Current Device
5SV6016-7KK16 5SV6Siemens · 5SV6 16A 2P 230V Residual Current Device
5SV6016-7KK40 5SV6Siemens · 5SV6 40A 2P 230V Residual Current Device
5SV6016-7KK06 5SV6Siemens · 5SV6 6A 2P 230V Residual Current Device
5SV1313-7KK04 5SV1Siemens · 5SV1 4A 2P Residual Current Device
5SV1313-7KK02 5SV1Siemens · 5SV1 2A 2P Residual Current Device
5SV1313-7KK16 5SV1Siemens · 5SV1 16A 2P Residual Current Device
5SV1313-7KK10 5SV1Siemens · 5SV1 10A 2P Residual Current Device
5SV1313-7KK06 5SV1Siemens · 5SV1 6A 2P Residual Current Device
2CSR255080R3404 DS201 C40 AC300ABB · Residual Current Circuit Breakers with Overcurrent Protection RCBO · ABB DS201 C40 AC300 - 1P+N RCBO, 40 A, 300 mA Type AC, 6 kA, 2 DIN-rail modules.
2CSR255080R3324 DS201 C32 AC300ABB · Residual Current Circuit Breakers with Overcurrent Protection RCBO · ABB DS201 C32 AC300 - 1P+N RCBO, 32 A, 300 mA Type AC, 6 kA, 2 DIN-rail modules.
2CSR255080R3204 DS201 C20 AC300ABB · Residual Current Circuit Breakers with Overcurrent Protection RCBO · ABB DS201 C20 AC300 - 1P+N RCBO, 20 A, 300 mA Type AC, 6 kA, 2 DIN-rail modules.
2CSR255080R3104 DS201 C10 AC300ABB · Residual Current Circuit Breakers with Overcurrent Protection RCBO · ABB DS201 C10 AC300 - 1P+N RCBO, 10 A, 300 mA Type AC, 6 kA, 2 DIN-rail modules.
2CSR255080R3064 DS201 C6 AC300ABB · Residual Current Circuit Breakers with Overcurrent Protection RCBO · ABB DS201 C6 AC300 - 1P+N RCBO, 6 A, 300 mA Type AC, 6 kA, 2 DIN-rail modules.
2CSR255080R1324 DS201 C32 AC30ABB · DS201 C32 AC30 1P+N 32A 10kA RCBO Residual Current Circuit Breaker with Overcurrent Protection
2CSR255080R1254 DS201 C25 AC30ABB · DS201 C25 AC30 1P+N 25A 10kA RCBO Residual Current Circuit Breaker with Overcurrent Protection
5SU1653-1KK40 5SU1Siemens · 5SU1 40A 2P 230V Residual Current Breaker (RCBO)
5SU1653-1KK32 5SU1Siemens · 5SU1 32A 2P 230V Residual Current Breaker (RCBO)
5SU1653-1KK25 5SU1Siemens · 5SU1 25A 2P 230V Residual Current Breaker (RCBO)
5SU1653-1KK20 5SU1Siemens · 5SU1 20A 2P 230V Residual Current Breaker (RCBO)
5SU1653-1KK16 5SU1Siemens · 5SU1 16A 2P 230V Residual Current Breaker (RCBO)
5SU1653-1KK10 5SU1Siemens · 5SU1 10A 2P 230V Residual Current Breaker (RCBO)
5SU1653-1KK06 5SU1Siemens · 5SU1 6A 2P 230V Residual Current Breaker (RCBO)
5SU1646-7FP32 5SU1Siemens · 5SU1 32A 4P 400V Residual Current Breaker (RCBO)
5SU1646-7FP25 5SU1Siemens · 5SU1 25A 4P 400V Residual Current Breaker (RCBO)
5SU1646-7FP20 5SU1Siemens · 5SU1 20A 4P 400V Residual Current Breaker (RCBO)
5SU1646-7FP16 5SU1Siemens · 5SU1 16A 4P 400V Residual Current Breaker (RCBO)
5SU1646-7FP10 5SU1Siemens · 5SU1 10A 4P 400V Residual Current Breaker (RCBO)
5SU1646-7FP06 5SU1Siemens · 5SU1 6A 4P 400V Residual Current Breaker (RCBO)
5SU1646-6FP32 5SU1Siemens · 5SU1 32A 4P 400V Residual Current Breaker (RCBO)
5SU1646-6FP25 5SU1Siemens · 5SU1 25A 4P 400V Residual Current Breaker (RCBO)
5SU1646-6FP20 5SU1Siemens · 5SU1 20A 4P 400V Residual Current Breaker (RCBO)
5SU1646-6FP16 5SU1Siemens · 5SU1 16A 4P 400V Residual Current Breaker (RCBO)
5SU1646-6FP10 5SU1Siemens · 5SU1 10A 4P 400V Residual Current Breaker (RCBO)
5SU1646-6FP06 5SU1Siemens · 5SU1 6A 4P 400V Residual Current Breaker (RCBO)
5SU1636-7FP32 5SU1Siemens · 5SU1 32A 3P 400V Residual Current Breaker (RCBO)
5SU1636-7FP25 5SU1Siemens · 5SU1 25A 3P 400V Residual Current Breaker (RCBO)
5SU1636-7FP20 5SU1Siemens · 5SU1 20A 3P 400V Residual Current Breaker (RCBO)
5SU1636-7FP16 5SU1Siemens · 5SU1 16A 3P 400V Residual Current Breaker (RCBO)
5SU1636-7FP10 5SU1Siemens · 5SU1 10A 3P 400V Residual Current Breaker (RCBO)
5SU1636-7FP06 5SU1Siemens · 5SU1 6A 3P 400V Residual Current Breaker (RCBO)
5SU1636-6FP32 5SU1Siemens · 5SU1 32A 3P 400V Residual Current Breaker (RCBO)
5SU1636-6FP25 5SU1Siemens · 5SU1 25A 3P 400V Residual Current Breaker (RCBO)
5SU1636-6FP20 5SU1Siemens · 5SU1 20A 3P 400V Residual Current Breaker (RCBO)
Can't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
RCBO (Residual Current Breakers with Overcurrent Protection) buying guide
What's in this range
- Siemens 5SU1 RCBOs in 2-pole 230 V and 4-pole 400 V versions.
- ABB DS201 RCBOs in 1P+N, 30 mA and 300 mA.
- Schneider Electric Acti9 iDPN N Vigi, iDPNa Vigi and iCV40 devices.
- Three-pole and four-pole RCBOs.
How to choose
- Rated current: match the cable and load, from 6 A to 40 A in this range.
- Curve: B for long cable runs and resistive loads, C for general use with moderate inrush.
- Sensitivity: 30 mA for socket circuits and personal protection.
- Breaking capacity: the kA value must exceed the prospective fault current at the board.
- Standard: IEC 61009-1, with RCD type AC or A for the load.
RCBO (Residual Current Breakers with Overcurrent Protection) questions
Why use an RCBO instead of an RCCB plus MCB?
An RCBO protects each circuit individually, so a leakage fault trips only that circuit. It also saves space in the board.
Is the neutral switched on a 1P+N RCBO?
On 1P+N devices the neutral is typically switched, so the module isolates both conductors. Check the datasheet of the specific part.
What is the lead time for RCBOs?
It depends on distributor stock for each part number. Stoklink ships from Turkey, EXW, and confirms timing with the quote.