Power Supplies
293 parts 3 sub-families
Power supplies from Siemens, Schneider Electric and ABB, with over 290 products that convert AC mains to stabilized 24 V DC for control circuits, PLCs and field devices. The range includes SITOP and Modicon DIN rail units, DC UPS and buffer modules, and redundancy and DC converter modules. Stoklink ships worldwide from Turkey and quotes project quantities on request.
3 sub-families of Power Supplies
-
207 parts
DIN Rail Power Supplies (24V DC)
DIN rail power supplies (24 V DC) from Siemens, Schneider Electric and ABB, with over 200 products for control panels, PLCs and field devices. -
35 parts
DC UPS & Buffer Modules
DC UPS and buffer modules from Siemens, with over 30 SITOP products that keep 24 V DC controls running when the mains fails. -
51 parts
Redundancy, Selectivity & DC Converter Modules
Redundancy, selectivity and DC converter modules from Siemens, with over 50 products that protect 24 V DC supply systems and drive DC motors.
293 parts
Showing 1–48ABLU3A24200 Modicon ABL Universal Schneider Electric
Schneider Electric · Modicon Universal regulated power supply, 380-500V AC 3-phase input, 24V DC 20A output, 480W, metal housing, DIN rail. Schneider ElectricABLS1A24031 Modicon ABL Optimized Schneider Electric
Schneider Electric · Modicon regulated switch-mode power supply, 100-240V AC single-phase input, 24V DC 3.13A output, 75W, IP20, DIN rail. Schneider ElectricABLU3A24100 Schneider Electric
Schneider Electric · 24 V DC / 10 A regulated power supply, 380-500 V AC three-phase input, DIN-rail, IP20. Schneider ElectricABLU3A24050 Schneider Electric
Schneider Electric · 24 V DC / 5 A regulated power supply, 380-500 V AC three-phase input, DIN-rail, IP20. Schneider ElectricABLS1A48100E Schneider Electric
Schneider Electric · 48 V DC / 10 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A48025 Schneider Electric
Schneider Electric · 48 V DC / 2.5 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A24200E Schneider Electric
Schneider Electric · 24 V DC / 20 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A24200 Schneider Electric
Schneider Electric · 24 V DC / 20 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A24100E Schneider Electric
Schneider Electric · 24 V DC / 10 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A24100 Schneider Electric
Schneider Electric · 24 V DC / 10 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A24050E Schneider Electric
Schneider Electric · 24 V DC / 5 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A24050 Schneider Electric
Schneider Electric · 24 V DC / 5 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A24030E Schneider Electric
Schneider Electric · 24 V DC / 3.2 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A24021 Schneider Electric
Schneider Electric · 24 V DC / 2.1 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A12100E Schneider Electric
Schneider Electric · 12 V DC / 10 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A12100 Schneider Electric
Schneider Electric · 12 V DC / 10 A regulated power supply, 100-240 V AC single-phase input, DIN-rail, IP20. Schneider ElectricABLS1A12062 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon Optimized power supply, 100-240 V AC in, 12 V DC / 6.25 A / 75 W out, 27 mm DIN rail. Schneider ElectricABLS1A12060E Modicon ABL2 Schneider Electric
Schneider Electric · Easy Modicon ABL2 power supply, 100-240 V AC in, 12 V DC / 6.3 A / 75.6 W out, DIN rail. Schneider ElectricABLM1A24025 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon modular power supply, 100-240 V AC in, 24 V DC / 2.5 A / 60 W out, 53 mm DIN rail. Schneider ElectricABLM1A24012 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon modular power supply, 100-240 V AC in, 24 V DC / 1.25 A / 30 W out, 36 mm DIN rail. Schneider ElectricABLM1A24006 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon modular power supply, 100-240 V AC in, 24 V DC / 0.625 A / 15 W out, 18 mm DIN rail. Schneider ElectricABLM1A24004 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon modular power supply, 100-240 V AC in, 24 V DC / 0.42 A / 10 W out, 18 mm DIN rail. Schneider ElectricABLM1A12042 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon modular power supply, 100-240 V AC in, 12 V DC / 4.17 A / 50 W out, 53 mm DIN rail. Schneider ElectricABLM1A12021 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon modular power supply, 100-240 V AC in, 12 V DC / 2.1 A / 25 W out, DIN rail mount. Schneider ElectricABLM1A12010 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon modular power supply, 100-240 V AC in, 12 V DC / 1 A / 12 W out, 18 mm DIN rail. Schneider ElectricABLM1A05036 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon modular power supply, 100-240 V AC in, 5 V DC / 3.6 A / 18 W out, 36 mm DIN rail. Schneider ElectricABL8RPS24100 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon power supply, 100-500 V AC in, 24 V DC / 10 A / 240 W out, 86 mm wide, DIN rail mount. Schneider ElectricABL8RPS24050 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon power supply, 100-500 V AC in, 24 V DC / 5 A / 120 W out, 56 mm wide, DIN rail mount. Schneider ElectricABL8RPS24030 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon power supply, 100-500 V AC in, 24 V DC / 3 A / 72 W out, 44 mm wide, DIN rail mount. Schneider ElectricABL8RPM24200 Modicon Power Supply Schneider Electric
Schneider Electric · Modicon power supply, 100-240 V AC in, 24 V DC / 20 A / 480 W out, DIN rail mount, 150% inrush boost. Schneider ElectricABL8RED24400 Phaseo Redundancy Module Schneider Electric
Schneider Electric · Phaseo redundancy module, 24 V DC, 40 A, backs up a bus across two parallel power supplies. DIN rail mount. Schneider ElectricABL8BUF24400 Phaseo Buffer Module Schneider Electric
Schneider Electric · Phaseo buffer module, 24 V DC input, 40 A continuous output, bridges brief mains interruptions without batteries. DIN rail mount. Schneider Electric6EP4683-6LB00-0AY0 Siemens
Siemens · LOGO! ICL230 inrush current limiter, 100-240V AC input/output, 5A continuous, limits inrush to 10A for 60ms. Siemens6EP4438-7FB00-3DX0 Siemens
Siemens · SITOP SEL1200 8-channel selectivity module, 24V DC/60A input, 8x2-10A adjustable outputs, DIN rail. Siemens6EP4438-7EB00-3DX0 Siemens
Siemens · Siemens 6EP4438-7EB00-3DX0 SITOP SEL1400, 8-channel selectivity module, 24V DC/60A in, 8x adjustable 2-10A out, IP20. Siemens6EP4437-8XB00-0CY0 Siemens
Siemens · SITOP CNX8600 4x10A expansion module for PSU8600 - 4 isolated 24V DC outputs, 10A each, 40A total, 97% efficient. Siemens6EP4437-7FB00-3DX0 Siemens
Siemens · Siemens SITOP SEL1200 selectivity module, 6EP4437-7FB00-3DX0, 8x1-5A adjustable, 24V/40A input, IP20. Siemens6EP4437-7FB00-3CX0 Siemens
Siemens · SITOP SEL1200 selectivity module, 4x 2-10A adjustable outputs, 24V DC/40A input, IP20. Siemens6EP4437-7EB00-3DX0 Siemens
Siemens · SITOP SEL1400 selectivity module, 8x 1-5A adjustable outputs, 24V DC/40A input, per-channel overcurrent trip. Siemens6EP4437-7EB00-3CX0 Siemens
Siemens · SITOP SEL1400 4-channel selectivity module, 24V DC/40A input, 4x adjustable 2-10A outputs. Siemens6EP4436-8XB00-0DY0 Siemens
Siemens · SITOP CNX8600 8x2.5A expansion module for PSU8600 - 8 isolated 24V DC outputs, 2.5A each, 20A total, NEC Class 2. Siemens6EP4436-8XB00-0CY0 Siemens
Siemens · SITOP CNX8600 expansion module for PSU8600, 4 outputs, 24V DC, 5A each, adjustable Siemens6EP4348-7RB00-0AX0 Siemens
Siemens · SITOP RED1200 redundancy module, decouples two 24V DC supplies, 80A output, 97.5% efficiency. Siemens6EP4347-7RB00-0AX0 Siemens
Siemens · Siemens 6EP4347-7RB00-0AX0 SITOP RED1200 redundancy module, 24/48V DC, 2x20A input, 40A combined output. Siemens6EP4346-7RB00-0AX0 Siemens
Siemens · SITOP RED1200 redundancy module, decouples two 10A supplies into a 24/48V, 20A DC output. Siemens6EP4297-8HB10-0XY0 Siemens
Siemens · SITOP BUF8600 buffer module for PSU8600, 300ms ride-through at 40A, electrolytic caps Siemens6EP4297-8HB00-0XY0 Siemens
Siemens · SITOP BUF8600 buffer module for PSU8600, 100ms ride-through at 40A, electrolytic caps SiemensCan't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
Power Supplies buying guide
What's in this range
- DIN Rail Power Supplies (24V DC) – single-phase and 3-phase units for control panels.
- DC UPS & Buffer Modules – keep 24 V DC loads running through short mains outages.
- Redundancy, Selectivity & DC Converter Modules – redundant supply, channel protection and SINAMICS DCM DC converters.
How to choose
- Output current: add up all 24 V loads and keep about 20 to 30 percent reserve for inrush and future additions.
- Input: single-phase 100-240 V AC, 3-phase 400-500 V AC or a wide-range input depending on the site network.
- Application type: standard control supply, DC UPS for ride-through, or redundancy module for two supplies in parallel.
- Mounting and environment: DIN rail width, operating temperature and derating, and protection class.
Power Supplies questions
How do I size a 24 V DC power supply?
Total the current of all connected loads, then add a reserve. Choose the next standard rating above that figure, for example 10 A or 20 A.
What is the difference between a DC UPS and a buffer module?
A DC UPS module uses a battery to carry the load, often for minutes. A buffer module uses capacitors to bridge outages of a few hundred milliseconds.
Can you supply Siemens SITOP units internationally?
Yes. Stoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and bulk quotes are available on request.